Finnigan ltq ft ultra mass spectrometer

Manufactured by Thermo Fisher Scientific

The Finnigan LTQ-FT Ultra mass spectrometer is a high-performance, hybrid ion trap-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. It is designed to provide high mass accuracy, high resolution, and sensitivity for a variety of analytical applications.

Automatically generated - may contain errors

2 protocols using finnigan ltq ft ultra mass spectrometer

1

Full-length Protein Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Full-length protein measurements were performed as described previously (Hoegl et al., 2018 (link)). Proteins were measured on a MassPREP On-Line Desalting Cartridge (Waters) on an Ultimate 3000 HPLC system (Dionex) coupled to a Finnigan LTQ-FT Ultra mass spectrometer (Thermo Fisher Scientific) with electrospray ionization (spray voltage 4.0 kV, tube lens 110 V, capillary voltage 48 V, sheath gas 60 arb, aux gas 10 arb, sweep gas 0.2 arb). Protein Deconvolution Software (Thermo Fisher Scientific, Cat# IQLAAEGABSFANOMBAQ) was used for data analysis and deconvolution.
+ Open protocol
+ Expand
2

Mass Spectrometry of Recombinant Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
Intact protein
MS of recombinant protein or proteins modified via the AMPylation assay were performed as described previously.45 (link) The samples were measured with an UltiMate 3000
HPLC system (Dionex) being equipped with a Massprep online desalting
cartridge (Waters) and coupled to a Finnigan LTQ-FT Ultra mass spectrometer
(Thermo Fisher Scientific). Ions were generated by electrospray ionization
(capillary temperature 275 °C, spray voltage 4.0 kV, tube lens
110 V, capillary voltage 48 V, sheath gas 60 arb, aux gas 10 arb,
sweep gas 0.2 arb) and separated with a flow rate of 0.4 mL/min and
the following gradient: (buffer A: 0.1% FA in H2O, buffer
B: 0.1% FA, 9.9% H2O in acetonitrile, 1 min hold 6% buffer
B, in 1.5 min increase buffer B to 95%, hold at 95% buffer B for 2
min, decrease to 6% buffer B in 0.2 min, stay at 6% buffer B for further
0.3 min). The instrumented was operated with a resolution of R = 200 000 and a mass range of m/z from 600 to 2000 while acquiring full scans.
The ProMass software for Xcalibur (Version 2.8) was used for deconvolution
(input m/z range: 600–2000;
output mass range: 15 000–30 000 Da).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!