Pe cy7 annexin 5 apoptosis detection set

Manufactured by Thermo Fisher Scientific

The PE)-Cy7 annexin V apoptosis detection set is a laboratory product used to detect and measure apoptosis in cells. It contains Annexin V conjugated with the fluorescent dye PE-Cy7, which binds to phosphatidylserine, a marker for apoptotic cells. The set also includes binding buffer and propidium iodide for additional cell analysis.

Automatically generated - may contain errors

3 protocols using pe cy7 annexin 5 apoptosis detection set

1

Cell Cycle and Apoptosis Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The cell cycle was analyzed by propidium iodide (PI) staining at the indicated time points as previously described (24 (link)). Apoptotic cells were detected by staining with the fixable viability dye eFluor 660 (catalog no. 650864; eBioscience, San Diego, CA) and a phycoerythrin (PE)-Cy7 annexin V apoptosis detection set (catalog no. 88810374; eBioscience) according to the instructions of the manufacturer. Flow cytometry was performed in a FACSCanto system (BD Biosciences, San Jose, CA), and analysis was performed with FlowJo (FlowJo, LLC, Ashland, OR).
+ Open protocol
+ Expand
2

Cell Cycle and Apoptosis Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell cycle analysis was performed by propidium iodide (PI) staining, and flow cytometry was carried out with a FACSCanto II flow cytometry system (BD Biosciences). The fixable viability dye eFluor 660 kit (650864; eBioscience) and a phycoerythrin (PE)-Cy7 annexin V apoptosis detection set (88810374; eBioscience) were used to detect apoptotic cells following the instructions of the manufacturer. The data were analyzed with the FlowJo software (BD Biosciences).
+ Open protocol
+ Expand
3

Cell Cycle Progression and Apoptosis Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell cycle and BrdU incorporation were performed at the indicated time points as previously described[12 (link)]. Cell cycle was analyzed by propidium iodide (PI) staining. BrdU incorporation was performed by pulsing cells with 10 μM BrdU for 1 h and then stained with a Pacific Blue monoclonal antibody to BrdU (Cat. B35129, Life Technologies, Grand Island, NY). Apoptotic cells were detected by Fixable Viability Dye eFluor 660 staining (Cat. 650864, eBioscience, San Diego, CA) and with a PE-Cy7 Annexin V Apoptosis Detection Set (Cat. 88810374, eBioscience) following the instructions of the manufacturer. Flow cytometry was performed in a FACSCanto System (BD Biosciences, San Jose, CA) and analysis was performed with FlowJo (FlowJo, LLC, Ashland, OR).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!