The largest database of trusted experimental protocols

Flex coil

Manufactured by Siemens
Sourced in Germany

The Flex Coil is a versatile lab equipment product designed to provide a flexible and adaptable solution for various experimental setups. The core function of the Flex Coil is to generate a controlled electromagnetic field, which can be used for a range of applications in scientific research and laboratory settings.

Automatically generated - may contain errors

7 protocols using flex coil

1

Fetal MRI Protocol for 3T Siemens Verio

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fetal MR exams were performed with a Siemens Verio 70-cm open-bore 3-T scanner with a light-weight (~550 g) abdominal 4-Channel Siemens Flex Coil. The MRI examination lasted 45 min. Images were collected with the following parameters and computed SAR values: (i) localizer [repetition time/echo time (TR/TE), 20/4.2 ms; 10-mm thickness; SAR = 0.21]; (ii) T2 anatomical (TR/TE, 3500/140 ms; 3-mm slice thickness; repeated 4–6 times; SAR = 0.53); (iii) echo planar imaging (EPI) BOLD (TR/TE, 2000/30 ms; 180 frames; 4-mm slice thickness; axial; repeated twice; SAR = 0.3); (iv) susceptibility weighted imaging (SWI) (TR/TE, 30/21.2 ms; 4-mm slice thickness; SAR = 0.06).
+ Open protocol
+ Expand
2

Fetal MRI Neuroimaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fetal MR exams were performed with a Siemens Verio 70-cm open-bore 3 Tesla scanner. An abdominal 4-Channel Siemens Flex Coil was placed around the maternal abdomen centered approximately at the fetal head. A T2 HASTE anatomical sequence (TR/ TE, 3500/ 140 ms; 3-mm slice thickness) was repeated six times, twice in each orientation. Echo planar imaging (EPI) BOLD (TR/ TE, 2000/ 30 ms; 180 frames; 4-mm slice thickness; axial) was performed for variable duration to accommodate readjustments to acquisition following fetal movement. The average number of BOLD fMRI time frames obtained per case was 349 (SD = 70). Specific absorption rates were extracted from fMRI scans for every subject.
+ Open protocol
+ Expand
3

Fetal Brain Functional Connectivity Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were conducted on a Siemens Verio 70 cm open-bore 3T system using a lightweight (500 g) abdominal four-channel Siemens Flex Coil centered approximately at the fetal head. Resting-state fMRI data were acquired using a gradient echo planar imaging (EPI) sequence, TR/TE 2,000/30 ms, flip angle 80°, 360 frames, slice thickness 4 mm (axial), voxel size 3.4 ×3.4 × 4 mm3, 12 min. When possible, rs-fMRI scans were repeated to attain up to 24 min of functional resting-state data per participant. The average specific absorption rate (SAR), an estimated measure of radio-frequency energy, was 0.20 W/kg (SD = 0.07).
+ Open protocol
+ Expand
4

Fetal MRI Examination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fetal magnetic resonance exams were performed with a Siemens Verio 70-cm open-bore 3-Tesla scanner with a lightweight abdominal Siemens Flex Coil. The MRI examination lasted 45 min. Images were collected with the following parameters and system-derived estimates of specific absorption rate: echo planar imaging blood oxygen level dependent, response time/echo time 2000/30 ms, minimum 180 frames, axial 4-mm slice, specific absorption rate = 0.22 (SD = 0.08). For the final sample of 96 cases included in all analyses, frame count, after excluding high motion frames, was range = 90 to 330, M = 155, SD = 48. Fetal MRI motion was included as covariate in all subsequent analyses for included participants.
+ Open protocol
+ Expand
5

3T MRI Acquisition Using Flex Coil

Check if the same lab product or an alternative is used in the 5 most similar protocols
We collected all imaging data with a 3T MRI scanner (Magnetom Vida, Siemens) at the Imaging Neuroscience Center at the University of Utah. We placed a Siemens flex coil (size: small) over the anterior and superior aspects of the subject’s head to maximize the signal-to-noise ratio of the acquired signals.
+ Open protocol
+ Expand
6

Fetal Brain Functional Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 3T Siemens Verio 70 cm open-bore system with a 550 g abdominal four-channel Siemens Flex coil was used to collected fetal resting state functional MRI data. For each participant, 360 axial frames (12 min) of EPI-BOLD data were collected with the following scan sequence parameters: TR = 2000 ms; TE = 30 ms; flip-angle: 80 degrees, slice-gap: none; voxel-size: 3.4 mm x 3.4 mm x 4 mm; matrix-size: 96 × 96 × 25 voxels.
+ Open protocol
+ Expand
7

Fetal Resting-State fMRI Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fetal functional brain imaging was performed with a Siemens Verio 70-cm open-bore 3-Tesla scanner with a lightweight abdominal Siemens Flex Coil (Siemens, Munich, Germany). Resting-state fMRI data were acquired using a gradient echo planar imaging sequence: TR/TE 2000/30 milliseconds, flip angle 80°, 360 frames, axial 4-mm slice thickness, voxel size 3.4 × 3.4 × 4 mm3, repeated twice. Between 12 and 24 minutes of fetal resting-state fMRI data were collected per participant. The average system derived estimates for specific absorption rate was 0.22 watts per kilogram (SD = 0.06).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.