The largest database of trusted experimental protocols

Gpc 50

Manufactured by Polymer Laboratories
Sourced in United Kingdom

The GPC 50 is a gel permeation chromatography (GPC) instrument designed for the analysis of polymer molecular weight distributions. It is a high-performance liquid chromatography (HPLC) system that separates polymer molecules based on their size or hydrodynamic volume. The GPC 50 provides accurate and reliable measurements of polymer molecular weight and molecular weight distribution.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using gpc 50

1

Size Exclusion Chromatography for Polymer Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Size exclusion chromatography was carried out using a Polymer Laboratories GPC 50 instrument fitted with a differential refractive index detector. The number-average molar mass (Mn), weight average molar mass (Mw) and polydispersity (Đ, Mw/Mn) were measured by SEC using HPLC-grade chloroform as eluent at 30 °C with 1 mL min−1 flow rate. PLgel guard column (50 × 7.5 mm, 8 μm) followed by a pair of PLgel Mixed-D columns (300 × 7.5 mm, 8 μm) were used for separation of the sample. Polystyrene standards of known Mn and Đ in the range of 100 Da– 500 kDa were used to calibrate the column. Molar mass and polydispersity were calculated using Polymer Labs Cirrus 3.0 software [18 ].
+ Open protocol
+ Expand
2

Polymer Characterization via GPC

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis was
performed using triple detection conditions with either a GPC50 (Polymer
Laboratories, UK; THF mobile phase) or a Malvern OmniSec System (Malvern,
UK; DMF mobile phase). Molecular weight and molecular weight distribution
of PPS polymers were determined using a PLgel 5 μm MIXED-D column
in series with a PLgel 3 μm MIXED-E operating online at 30 °C.
THF was used as an eluent at a flow rate of 1.0 mL/min. Two linear
polystyrene standards (Malvern, UK) for calibration (narrow) and for
verification (broad) were used for the analysis of the polymers. Block
copolymers of PPS with polyacrylamides were analyzed using a D3000
column operating online at 50 °C with HPLC grade DMF containing
0.1% LiBr as the mobile phase at a flow rate of 0.8 mL/min. Calibration
was performed using a poly(methyl methacrylate) standard.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!