The largest database of trusted experimental protocols

27 protocols using resistant starch assay kit

1

Determination of Resistant Starch in Cooked Rice

Check if the same lab product or an alternative is used in the 5 most similar protocols
The concentration of resistant starch (RS% dw) in the cooked rice was determined based on the AOAC Method 2,002,02 (AOAC International, 2007) using a Resistant Starch Assay kit from Megazyme (K-RSTAR 08/11, Wicklow, Ireland) and expressed as % resistant starch/cooked rice (dry wt basis) as described in Chen et al. [13 (link)]. Briefly, the freshly cooked rice was minced and then a 0.5 g portion was weighed and incubated in a shaking water bath with pancreatic α-amylase and amyloglucosidase for 16 h at 37 °C. An equal volume of ethanol was added to the digest to precipitate the RS. After centrifugation, the pellet was washed twice in 50% v/v ethanol. The RS in the pellet was dissolved in 2 M KOH, neutralized with acetate buffer and hydrolyzed to glucose with amyloglucosidase. After adding glucose oxidase/peroxidase reagent to the samples the absorbance of each solution was determined using a spectrophotometer at 510 nm. The glucose concentration was then converted to RS.
+ Open protocol
+ Expand
2

Comprehensive Chemical Characterization of Pasta

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemical composition was assessed both on raw materials and dry pasta. Moisture was measured by a thermobalance (Sartorius MA 40, Goettingen, Germany) at 120 °C and all analytical data were expressed as dry weight (dw).
Total starch (TS) content was determined according to the Official Method 996.11 [28 ], by Total Starch Assay Kit (Megazyme, Bray, Ireland). Amylose content was determined using the Megazyme Amylose/Amylopectin assay kit. Resistant starch (RS) content was determined according to the Official Method 2002.02 [29 ], using Resistant Starch Assay Kit (Megazyme). Total dietary fiber (TDF) content was measured using the enzymatic kit Bioquant (Merck, Darmstadt, Germany) according to the Official Method 991.42 [30 ]. Ash content was determined according to the Official Method 08-01.01 [31 ]. Protein content was determined by micro-Kjeldhal nitrogen analysis, according to the ICC 105-2 method [32 ], using as conversion factor N × 6.25. Total antioxidant capacity (TAC) was determined according to Martini et al. [33 (link)].
+ Open protocol
+ Expand
3

Green Banana Flour Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Flour from five green banana cultivars, namely Grande Naine, Pisang Awak, Finger Rose, FHIA-01 and Du Roi, was kindly provided by the Agricultural Research Counsel (ARC) Tropical and Subtropical Crops, Nelspruit, Mbombela in South African. All reagents were analytical grade, Trolox, Folin–Ciocalteu reagent, gallic acid and quercetin were purchased from Sigma-Aldrich Pty. Ltd. (Johannesburg, South Africa). The resistant starch assay kit and the amylose/amylopectin kit were purchased from Megazyme Ltd. (Johannesburg, South Africa).
+ Open protocol
+ Expand
4

In Vitro Starch Digestibility Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The in vitro digestibility of starch was evaluated on the basis of total starch content (TS) and potentially resistant starch (RS) determined after digestion in vitro [40 (link)]. Starch contained in the residues remaining after the in vitro digestion was hydrolyzed with thermostable α-amylase and amyloglucosidase according to AOAC Official Method 996.11 (Resistant Starch Assay Kit, Megazyme) [41 (link)]. Starch digestibility in vitro was calculated as follows:
where: SD = in vitro digestibility of starch, TS = total starch content, and RS = content of starch after in vitro digestion
+ Open protocol
+ Expand
5

Determining Resistant Starch Content

Check if the same lab product or an alternative is used in the 5 most similar protocols
The content of resistant starch (RS) of native and hydrothermally modified starch samples were determined according to the analysis procedure provided by the Resistant Starch Assay Kit (Megazyme International Ireland Ltd. Co., Wicklow, Ireland).
+ Open protocol
+ Expand
6

Measuring Resistant Starch Content

Check if the same lab product or an alternative is used in the 5 most similar protocols
The resistant starch content was determined with Resistant Starch Assay kit (Megazyme, Bray, Ireland) with the description of Association of Official Analytical Chemists (AOAC) 2002.02.
+ Open protocol
+ Expand
7

Comprehensive Analysis of Dog Food Nutrient Profiles

Check if the same lab product or an alternative is used in the 5 most similar protocols
The dog food samples were analyzed without pre-drying. To determine dry matter (DM) content, the samples were dried at 103 °C for 16 h, and then placed in a desiccator to cool before weighing36 . For ash determination, samples were incinerated at 550 °C for three hours and then cooled in a desiccator before weighing. The Kjeldahl method37 was applied to determine nitrogen content, using a 2020 digester and a 2400 Kjeltec analyzer (FOSS Analytical A/S, Hilleröd, Denmark). Crude protein was then calculated as N × 6.25. Crude fat was analyzed in accordance with Commission Directive EC/152/200938 , on a Soxtec extraction unit (FOSS Analytical A/S, Hilleröd, Denmark). Crude fiber was analyzed as previously described39 . Gross energy (GE) was measured on a Parr isoperobol Bomb Calorimeter 6300 (Parr Instrument Company, Moline, Illinois, USA). Total dietary fiber (TDF) as well as soluble and insoluble dietary fiber were analyzed in accordance with AOAC 991.43 using a Total Dietary Fiber Assay Kit (Megazyme, Bray, Ireland), while resistant and non-resistant starch were analyzed according to AOAC 2002.02 using a Resistant Starch Assay Kit (Megazyme, Bray, Ireland).
+ Open protocol
+ Expand
8

Quantifying Banana Starch Composition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Amylose content as a percentage of total starch was analyzed using the amylose/amylopectin assay kit manufactured by Megazyme International Ireland Ltd. (Bray, Ireland). Resistant starch content in the banana starch sample was measured using the resistant starch assay kit developed by Megazyme International Ireland Ltd. (Bray, Ireland).
+ Open protocol
+ Expand
9

Starch and Protein Analysis Assays

Check if the same lab product or an alternative is used in the 5 most similar protocols
Granule-bound starch synthase I enzymatic activity was determined using the GBSSI enzymatic activity assay kit (Solarbio Science & Technology, Beijing, China) according to the manufacturer′s instructions. Total starch, amylose, and resistant starch contents in GP and M2-1105 were determined using the total starch (AA/AMG) Assay Kit, Amylose/Amylopectin Assay Kit, and Resistant Starch Assay Kit (Megazyme, Wicklow, Ireland), respectively. Protein content was determined using the automatic Kjeldahl apparatus equipment (Foss Analytical Kjeltec™ 8400 series), as previously described (Yang et al., 2019 (link)). Each sample was analyzed in triplicate.
+ Open protocol
+ Expand
10

Quantifying Resistant and Total Starch

Check if the same lab product or an alternative is used in the 5 most similar protocols
The resistant starch (RS) content of the samples was measured according to the resistant starch assay kit from Megazyme International (Wicklow, Ireland) (AACC method 32-40). Total starch (TS) was measured using the Total starch assay kit from Megazyme (AACC method 76-13).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.