Laboratory data included complete blood count (Cell-Dyn Sapphire platform, Abbott Diagnostics, United States), coagulation, and kidney and liver function tests collected upon admission. In addition, baseline, peak, and prior-to-CTPA values of the following biomarkers were analyzed in each patient: fibrinogen, D-dimer (reported as D-dimer units (DDUs), ACL TOP 700, Instrumentation Laboratory), C-reactive protein (CRP), lactate dehydrogenase (LDH), erythrocyte sedimentation rate (ESR), and ferritin. In addition, high sensitive troponin I, interleukin-6 (IL-6), interleukin-10 (IL-10) (ELISA, R&D systems), N-terminal pro hormone B-type natriuretic peptide (NT pro-BNP) (Test 1 THL Module, ALI FAX; Architect platform, Abbott Diagnostics), and fibrinogen were also measured. Blood gas analyses were performed on the GEM 4000 platform (Werfen, Spain). D-dimer-to-ferritin, D-dimer-to-LDH, and D-dimer-to-CRP ratios were calculated.
Cell dyn sapphire platform
The Cell-Dyn Sapphire is an automated hematology analyzer platform developed by Abbott. It is designed to perform complete blood count (CBC) and differential analysis on human blood samples. The platform utilizes multi-angle light scatter and impedance-based technology to provide comprehensive cell analysis and enumeration.
2 protocols using cell dyn sapphire platform
Evaluation of COVID-19 Patients with Pulmonary Embolism
Laboratory data included complete blood count (Cell-Dyn Sapphire platform, Abbott Diagnostics, United States), coagulation, and kidney and liver function tests collected upon admission. In addition, baseline, peak, and prior-to-CTPA values of the following biomarkers were analyzed in each patient: fibrinogen, D-dimer (reported as D-dimer units (DDUs), ACL TOP 700, Instrumentation Laboratory), C-reactive protein (CRP), lactate dehydrogenase (LDH), erythrocyte sedimentation rate (ESR), and ferritin. In addition, high sensitive troponin I, interleukin-6 (IL-6), interleukin-10 (IL-10) (ELISA, R&D systems), N-terminal pro hormone B-type natriuretic peptide (NT pro-BNP) (Test 1 THL Module, ALI FAX; Architect platform, Abbott Diagnostics), and fibrinogen were also measured. Blood gas analyses were performed on the GEM 4000 platform (Werfen, Spain). D-dimer-to-ferritin, D-dimer-to-LDH, and D-dimer-to-CRP ratios were calculated.
Maternal Inflammation Assessment Protocol
The remaining blood sample was centrifuged at 2,500 rpm for 10 min to isolate the plasma. The different plasma aliquots were stored at −80
The inflammatory cytokines were analyzed on plasma samples by multiplex technique using the Human High Sensitivity Cytokine Base Kit A (Magnetic Luminex® Performance Assay, R&D Systems®, Inc.) following the indicated procedure. For each one of the cytokines, analyzed the detection limits and coefficients of variation were 0.29 pg/mL and 5.2% (TNF-α), 0.08 pg/mL and 5.3% (IL-1β), 0.14 pg/mL and 5.2% (IL-6), 0.04 pg/mL and 6.6% (IL-8), 0.21 pg/mL and 5.4% (IL-10).
Following the delivery day, anthropometric and neonatal variables were collected from all newborns. Laboratory researchers were blinded to maternal status.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.