The largest database of trusted experimental protocols

Lc ms grade acetic acid

Manufactured by Honeywell
Sourced in Germany

LC-MS grade acetic acid is a high-purity solvent used in liquid chromatography-mass spectrometry (LC-MS) applications. It serves as a mobile phase component, ensuring accurate and reliable analytical results.

Automatically generated - may contain errors

3 protocols using lc ms grade acetic acid

1

Quantification of MDA via HPLC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
MDA-salt (MDA tetrabutyl ammonium salt) (96%, neat) was obtained from Sigma-Aldrich (St. Louis, MO, USA). MDA-d2 (1,1,3,3-tetraethoxypropane-d2, stock solution: 98%) was obtained from Cambridge Isotope Laboratories (Tewksbury, MA, USA). DNPH reagent (2,4-Dinitrophenylhydrazine) in a solid form containing 25% water, was obtained from Carlo Erba Reagents (Chaussée du Vexin, Val de Reuil, France). HPLC grade methanol (≥99.9%) was obtained from Merck (Buchs, Switzerland). LC-MS grade solvents, methanol (≥99.95%) and acetonitrile (≥99.9%) were obtained from Carlo Erba Reagents (Chaussée du Vexin, Val de Reuil, France). LC-MS grade acetic acid was obtained from Honeywell (Seelze, Germany). High purity water was produced in our laboratory with a MilliQ Advantage water purification system (18.2 MΩ·cm at 25 °C, <3 ppb total organic carbon; Merck, Schaffhouse, Switzerland).
+ Open protocol
+ Expand
2

Quantification of Oxidative Stress Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
8-OHdG (≥98%) (2-amino-9-[(2R,4S,5R)-4-hydroxy-5-(hydroxymethyl)oxolan-2-yl]-1,7-dihydropurine-6,8-dione) in a solid form was obtained from Merck (Buchs, St. Gallen, Switzerland). [15N5]-8-OHdG as internal standard (IS) was obtained from Cambridge Isotope Laboratories (Tewksbury, MA, USA). 8-Isoprostane ((5Z,8β,9α,11α,13E,15S)-9,11,15-trihydroxyprosta-5,13-dien-1-oic acid) in a solution ≥ 95%, and its deuterated IS 8-Isoprostane-d4 ((5Z,8β,9α,11α,13E,15S)-9,11,15-trihydroxyprosta-5,13-dien-1-oic-3,3,4,4-d4 acid), were obtained from Cayman Chemical (Ann Arbor, MI, USA). HPLC grade methanol (≥99.9%) was obtained from Merck (Buchs, Switzerland). LC-MS grade solvents; methanol (≥99.95%) and acetonitrile (≥99.9%) were obtained from Carlo Erba Reagents (Chaussée du Vexin, Val de Reuil, France). Butylated hydroxytoluene (BHT) ≥ 99% was obtained from Sigma-Aldrich Produktions GmbH (Steinheim Germany). LC–MS grade acetic acid was obtained from Honeywell (Seelze, Germany). Ultrapure water was produced in our laboratory with a Milli-Q Advantage water purification system (18.2 MΩ.cm at 25 °C, <3 ppb total organic carbon).
+ Open protocol
+ Expand
3

Quantification of Oxidative Stress Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
8-OxodG (≥98% (TLC), CAS Number 88847-89-6) was obtained from Merck KGaA (Buchs, St. Gallen, Switzerland). The isotopically labelled [15N5]-8-oxodG (CAS Number 569649-11-2) was used as the internal standard (IS) and bought from Cambridge Isotope Laboratories, Inc. (Tewksbury, MA, USA). 8-Isoprostane ((5Z,8β,9α,11α,13E,15S)-9,11,15-trihydroxyprosta-5,13-dien-1-oic acid; ≥95%, CAS Number 27415-26-5) and its deuterated isomer (IS) 8-Isoprostane-d4 ((5Z,8β,9α,11α,13E,15S)-9,11,15-trihydroxyprosta-5,13-dien-1-oic-3,3,4,4-d4 acid; CAS Number 211105-40-7), were obtained from Cayman Chemical (Ann Arbor, MI, USA). LC-MS grade solvents, water, methanol, and acetonitrile, were obtained from Carlo Erba Reagents (Chaussée du Vexin, Val de Reuil, France). LC-MS grade acetic acid was obtained from Honeywell (Seelze, Germany). MilliQ water was produced in the laboratory with a water purification system (MilliQ Advantage) from Merck (Schaffhausen, Switzerland). Solid phase extraction (SPE) cartridges (Chromabond C18 ec SPE 500 mg 3 mL) were purchased from Macherey-Nagel (Oensingen, Switzerland).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!