The largest database of trusted experimental protocols

Inova unity 200 spectrometer

Manufactured by Agilent Technologies
Sourced in Italy

The Inova Unity 200 spectrometer is a laboratory instrument designed for nuclear magnetic resonance (NMR) spectroscopy. It is capable of performing high-resolution NMR measurements to analyze the molecular structure and composition of chemical samples.

Automatically generated - may contain errors

2 protocols using inova unity 200 spectrometer

1

Synthesis of Antioxidant Ester Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
The synthesis of esters IDETRL and IDELIP was reported in Scheme 1. Commercially-available idebenone and trolox or lipoic acid were reacted to obtain esters IDETRL and IDELIP, respectively, in the presence of 4-DMAP and DCC in dry acetonitrile as solvent. This procedure had already been adopted for the preparation of IDETRL, known as Fe-Aox29 [47 (link)]; in this case, some slight modifications were used.
Infrared spectra were recorded on a Perkin Elmer series FTIR 1600 spectrometer (Milan, Italy) in NaBr disks. 1H-NMR spectra were performed on a Varian Inova Unity 200 spectrometer (200 MHz) (Milan, Italy) in DMSO-d6 or CDCl3 solution. Chemical shifts are given in δ values (ppm), using tetramethylsilane as the internal standard; coupling constants (J) are given in Hz. Signal multiplicities are characterized as s (singlet), t (triplet), and m (multiplet). Reaction progress and purity of all the synthesized compounds were checked on TLC (an aluminum sheet coated with silica gel 60 F254, Merck, Darmstadt, Germany) and visualized by UV light at 254 and 366 nm as wavelength). Purification of synthesized compounds by flash column chromatography was performed using Merck silica gel (0.040–0.063 mm).
+ Open protocol
+ Expand
2

Characterization of Synthesized Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points of newly synthesized derivatives were determined with an Electrothermal IA9200 using glass capillary tubes. Infrared spectra were recorded on a Perkin–Elmer FT IR 1600 spectrometer in KBr disks. Elemental analyses for C, H, and N were within 70.4% of theoretical values and were performed on a Carlo Erba Elemental Analyzer Mod. 1108 apparatus. 1H NMR spectra were recorded at 200 MHz on a Varian Inova Unity 200 spectrometer in DMSO-d6 or chloroform-d solution. Chemical shifts are given in δ values (ppm), using tetramethylsilane as the internal standard; coupling constants (J) are given in hertz (Hz). Signal multiplicities are characterized as s (singlet), d (doublet), t (triplet), q (quartet), m (multiplet), and br (broad signal). All the synthesized compounds were tested for purity on TLC (aluminum sheet coated with silica gel F254, Merck) and visualized by UV (λ 254 and 366 nm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!