Bioaccord

Manufactured by Waters Corporation
Sourced in United States

The BioAccord is a liquid chromatography-mass spectrometry (LC-MS) system designed for routine analysis of biotherapeutics and biomolecules. It provides high-resolution, accurate-mass data to support characterization and quantitation of complex biomolecules.

Automatically generated - may contain errors

2 protocols using bioaccord

1

Protein Analysis by LC-MS with TOF

Check if the same lab product or an alternative is used in the 5 most similar protocols
Proteins were diluted to 1 µM with 0.1% (v/v) formic acid and injected onto a C4 BEH 1.7 µm, 1.0 × 100 mm, UPLC column using the Acquity I class LC (Waters) system. Proteins were eluted with a 15 min gradient of acetonitrile (2% (v/v) to 80% (v/v)) in 0.1% (v/v) formic acid using a flow rate of 50 µl min−1. The analytical column outlet was directly interfaced through an electrospray ionization source, with a time-of-flight (TOF) mass spectrometer (BioAccord, Waters). Data were acquired over a m/z range of 300–8,000, in positive-ion mode with a cone voltage of 40 V. Scans were summed together manually and deconvoluted using MaxEnt1 (Masslynx, Waters). The parameters used were as follows; input m/z range (Da): 600–2,000; output mass range (Da): 30000–60000; TOF resolution: 10000.00; and iterate to convergence.
+ Open protocol
+ Expand
2

Characterization of Chemical Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
General Methods Physical data were measured as follows: 1 H, 13 (link) C, and 31 P-NMR spectra were recorded at 400 or 500 MHz, 100 or 125 MHz, and 162 or 202 MHz instruments (Bruker FT-NMR AV400 or AV500), respectively in CDCl 3 or dimethyl sulfoxide (DMSO)-d 6 as the solvent with tetramethylsilane or H 3 PO 4 as an internal or external standard. Chemical shifts are reported in parts per million (ppm), and signals are expressed as s (singlet), d (doublet), t (triplet), m (multiplet), or br (broad). All exchangeable protons were detected by addition of D 2 O. Mass spectra were measured on a SQD2 (Waters, U.S.A.) and BioAccord (Waters). TLC was done on Merck Kieselgel F254 precoated plates. Silica gels used for column chromatography were KANTO Chemical silica gel 60 and KANTO Chemical silica gel 60N (neutral).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!