Analytical Protocol for Phenolic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents and reagents used for analysis were HPLC- and analytical-grade. Gallic acid (≥98.0%), 3,4-dihydroxybenzoic acid (≥97.0%), 4-hydroxybenzoic acid (≥99.0%), 2,4-dihydroxybenzoic acid (≥97.0%)), vanillic acid (≥97.0%), caffeic acid (≥98.0%), syringic acid (≥95.0%), p-coumaric acid (≥98.0%), ferulic acid (≥99.0%), sinapinic acid (≥98.0%), rutin (≥95.0%) quercetin 3-β-d-glucoside (≥99.0%), benzoic acid (≥99.5%), kaempferol 3-O-β–rutinoside (≥98.0%), quercetin (≥95.0%), cinnamic acid (≥99.0%), and kaempferol (≥97.0%) were purchased from Sigma-Aldrich (St. Louis, MO, USA).
Stock standard solutions were prepared by dissolving approximately 1 mg of each substance in a 1 mL aliquot of methanol (1000 μg/mL). A mixed standard solution containing 10 μg/mL was subsequently prepared in methanol and stored at 4 °C prior to use.
+ Open protocol
+ Expand
2

UPLC Identification of Polyphenols

Check if the same lab product or an alternative is used in the 5 most similar protocols
An ultra performance liquid chromatography (UPLC) system (Waters, Milford, MA, USA) equipped with a binary solvent delivery pump, auto-sampler, and a photodiode array (PDA) detector was used to identify individual polyphenols, as described previously [22 (link)]. The UPLC settings used in this study are summarized in Table 1. The mobile phase consisted of a binary solvent system comprising water (Solvent A) and acetonitrile (Solvent B) supplemented with 0.1% formic acid. A total of 17 phenolic compounds such as, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, 2,4-dihydroxybenzoic acid, vanillic acid, caffeic acid, syringic acid, p-coumaric acid, ferulic acid, sinapic acid, rutin, quercetin 3-β-D-glucoside, benzoic acid, kaempferol 3-O-β-rutinoside, quercetin, cinnamic acid, and kaempferol were purchased from Sigma-Aldrich (St. Louis, MO, USA) and used as standards. For each standard compound, a methanol solution was prepared, resulting in a final concentration of 1000 ng/mL. A mixture of all standard compounds was then utilized to establish the calibration curve. The polyphenol content of each sample was calculated using the method described previously [22 (link)] with minor modification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!