Signa excite 3t

Manufactured by GE Healthcare
Sourced in United States

The Signa EXCITE 3T is a magnetic resonance imaging (MRI) system developed by GE Healthcare. It operates at a field strength of 3 Tesla, which allows for high-quality imaging and enhanced diagnostic capabilities. The Signa EXCITE 3T provides advanced imaging technology to healthcare professionals.

Automatically generated - may contain errors

Lab products found in correlation

25 protocols using signa excite 3t

1

Diffusion Tensor Imaging at 3T MRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
All magnetic resonance (MR) examinations were performed using a 3 T MR system (Signa EXCITE 3T; GE Health-care, Waukesha, WI, USA). Diffusion tensor images were acquired by a single-shot, spin-echo echo-planar sequence (TR/TE=12,000/83.3 ms; 4 mm slice thickness; no gap; field of view=26 cm; number of excitations=1). Diffusion gradients were applied for the three axes simultaneously around the 180-degree pulse (b value=1,000 s/mm2). The diffusion properties were measured in 25 non-collinear directions.
+ Open protocol
+ Expand
2

3D-FSPGR and DTI Brain Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were performed on a 3.0-Tesla scanner (Signa EXCITE 3T; GE Healthcare, Milwaukee, WI, USA) using a dedicated eight-channel phased-array coil (USA Instruments Aurora, OH, USA). Three-dimensional fast spoiled gradient recalled acquisition with steady state (3D-FSPGR) images of the whole head were obtained with the following parameters:10/4.1/700 (repetition time ms/echo time ms/inversion time), a flip angle of 10, a 24- cm field of view and 1.2-mm-thick sections with 0.47 × 0.47 × 0.6 mm3 resolution. In addition, diffusion tensor images (DTIs) were also obtained assuming other hypothesis study. Although these DTIs were not used for this study’s analysis, the images were used to check whether the subject brains had any abnormalities.
+ Open protocol
+ Expand
3

3T MRI Brain Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All MR examinations were performed with a 3T MR system (Signa EXCITE 3T; GE Healthcare, Milwaukee, WI) with an 8-channel brain-phased array coil. The brain volume data were obtained with a three-dimensional fast spoiled gradient recalled acquisition with steady state (3D-FSPGR), which was acquired with parameters of 10/4.1/700 (repetition time msec/echo time msec/inversion time msec), a flip angle of 10 degree, a 24-cm field of view, and 1.2-mm-thick sections with 0.47×0.47×1.2 mm resolution. Diffusion tensor images were acquired using a single-shot, spin-echo echo-planar sequence with the following parameters: TR/TE = 12000/83.3 msec, 4-mm slice thickness, no gap, 26-cm field of view; number of excitation = 1, and a spatial resolution of 1.02×1.02×4 mm. Diffusion gradients (b value of 1,000 sec/mm2) were always applied on each axis simultaneously around the 180-degree pulse. The diffusion properties were measured along 25 noncollinear directions. The structural distortion of diffusion-weighted MR images was corrected based on each T2-weighted planar image (b = 0 sec/mm2) [20] (link).
+ Open protocol
+ Expand
4

Multiparametric MRI of Parkinson's Disease

Check if the same lab product or an alternative is used in the 5 most similar protocols
All studies were performed with a 3T MR system (Signa EXCITE 3T; GE Healthcare, Milwaukee, WI) using a dedicated eight-channel phased-array coil (USA Instruments, Aurora, OH). The PADRE was performed with a 3D multi-echo spoiled GRE sequence.19 (link) The imaging parameters included: axial or coronal planes covering the whole globus pallidus (GP); 11 echo times; first echo time, 4.5 msec; uniform echo time spacing, 5 msec; repetition time, 58.4 msec; flip angle, 15°; bandwidth per pixel, ± 62.5 Hz; field of view, 22 × 16.5 cm; acquisition matrices, 320 × 416; slice thickness, 1.5 mm; number of slices, 1848 and an imaging time of 7 min 1 sec. A parallel imaging method (the array spatial sensitivity encoding technique) was used with a reduction factor of 2. For the 3D multi-echo spoiled GRE sequence, we acquired 33 axial and 17 coronal-plane images of the 50 NC, and all images of patients with PD were obtained in axial-plane images. All the subjects were also imaged with T2WI and obtained with axial plane, and imaging parameters were as follows: echo time, 85 msec; repetition time, 4000 msec; flip angle, 90°; slice thickness, 5 mm; field of view, 22 × 22 cm; acquisition matrices, 512 × 512 and an imaging time of 3 min 20 sec.
+ Open protocol
+ Expand
5

3T MRI Brain Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The MRI data were obtained using the 3T MR System (Signa EXCITE 3T; GE Healthcare, Wankesha, WI, USA) with an 8-channel brain phased-array coil. The original T1 images were acquired using a 3D fast-spoiled gradient recalled acquisition with a steady state. The acquisition parameters were as follows: repetition time in ms/echo time in ms/inversion time in ms=10/4.1/700; flip angle=10; field-of view=24 cm; section thickness=1.2 mm, and resolution=0.9×0.9×1.2 mm. All the images were corrected for image distortion owing to gradient nonlinearity using the Grad Warp software program34 (link) and intensity inhomogeneity using the “N3” function.35 (link)
+ Open protocol
+ Expand
6

Optimized MRI Acquisition Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were performed using a 3T MR system (Signa EXCITE 3T; GE Healthcare; Waukesha, WI, USA) with an eight-channel brain phased-array coil. Original T1 images were acquired by three-dimensional fast-spoiled gradient recalled acquisition with a steady state. The acquisition parameters were as follows: repetition time, 10 ms; echo time, 4.1 ms; inversion time, 700 ms; flip angle, 10; field-of-view, 24 cm; section thickness, 1.2 mm; and resolution, 0.9 × 0.9 × 1.2 mm. All images were corrected for image distortion due to gradient non-linearity using the Grad Warp software program25 (link),49 (link) and for intensity in homogeneity with the “N3” function.26 (link),50 (link)
+ Open protocol
+ Expand
7

3T MRI Structural Brain Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All brain MRI data were obtained using the same protocol on a single 3T MRI scanner (Signa EXCITE 3T; GE Healthcare, Wankesha, WI, USA) with an 8-channel brain phased-array coil. Original T1WI were acquired in the steady state using a 3D fast-spoiled gradient recalled sequence with the following parameters: repetition time, 10 ms; echo time, 4.1 ms; inversion time, 700 ms; flip angle, 10; field-of view, 24 cm; section thickness, 1.2 mm; and resolution, 1.0 × 1.0 × 1.2 mm. All images were corrected for distortion due to gradient non-linearity using Grad Warp software31 (link) and for intensity inhomogeneity using the “N3” function32 (link).
+ Open protocol
+ Expand
8

High-Resolution 3T MRI Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI data were obtained on a 3T MR system (Signa EXCITE 3T; GE Healthcare, Waukesha, WI) with an 8-channel brain phased-array coil. Images were acquired by three-dimensional fast-spoiled gradient recalled acquisition (3D-FSPGR). The acquisition parameters were: repetition time/echo time, 10/4.1 ms; flip angle, 10°; field of view, 24 cm; and resolution, 0.9 × 0.9 × 1.2 mm. All images were corrected for image distortion due to gradient non-linearity using the “Grad Warp” software program (Jovicich et al., 2006 (link)).
+ Open protocol
+ Expand
9

3T MRI Structural Covariance Network Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Magnetic resonance imaging was performed using a 3T MR system (Signa EXCITE 3T; GE Healthcare, Waukesha, WI, USA) equipped with an eight-channel brain phased-array coil. Rather than assessing functional connectivity at rest, this study utilized a structural covariance network based on brain structural imaging. The original T1 images were acquired using three-dimensional (3D) fast-spoiled gradient-recalled acquisition in a steady state. The acquisition parameters were set as follows: repetition time, 10 ms; echo time, 4.1 ms; inversion time, 700 ms; flip angle, 10°; field-of-view, 24 cm; section thickness, 1.2 mm; and resolution, 0.9 × 0.9 × 1.2 mm. All images underwent correction for image distortion due to gradient non-linearity using the Grad Warp software program (19 (link)) and for intensity inhomogeneity with the “N3” function (20 (link)).
+ Open protocol
+ Expand
10

3-T MRI Neuroimaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All studies were performed using the 3-T MRI system (Signa EXCITE 3 T; GE Healthcare) with a dedicated eight-channel phased-array coil (USA Instruments Aurora, OH, USA).
All patients and controls underwent brain MRI according to our standard protocol, including T2WI, FLAIR imaging and T1-weighted imaging (T1WI). T2WI, FLAIR imaging and T1WI (spin-echo imaging) were obtained on the axial planes. For T1WI (3D fast spoiled gradient-echo imaging), we used three cross-section images (coronal, axial, and sagittal) reconstructed from the images obtained on the sagittal plane. The imaging parameters (repetition time ms/echo time ms/inversion time/NEX/imaging time) were 4,500/85/NA/1/2 min and 10 s for T2WI, 12,000/140/2,600/2/3 min and 20 s for FLAIR imaging and 400/4/NA/2/2 min and 40 s for spin-echo T1WI. The T2WI, T1WI, and FLAIR images were acquired at a section thickness of 4 mm, an intersection gap of 2.5 mm, a field of view of 22 cm and a matrix of 256 × 192. The following parameters were used for spoiled gradient-echo imaging: repetition time ms/echo time ms, 10/4; flip angle, 10°; bandwidth, 42 kHz; section thickness, 1.2 mm; matrix, 256 × 256; field of view, 24 × 24 cm; imaging time, 3 minutes and 56 seconds.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!