The largest database of trusted experimental protocols

4 protocols using ccr7 apcefluor 780

1

Multiparameter Flow Cytometry Analysis of T Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
The remaining blood was used to isolate PBMCs using previously described methods [25] (link). PBMCs were thawed, washed and stained with LIVE/DEAD Fixable Aqua Dead Cell Stain Kit (Invitrogen), and then stained with the following fluorescently-conjugated monoclonal antibodies: CD8-QDOT 605 and CD4-PE-Texas Red (Invitrogen, Grand Island, NY, USA); CD3-Pacific Blue, CCR5-PE-Cy5, CD38-PE, HLA-DR-FITC, PD-1 Alexa Fluor 647, CD45RA-PE-Cy7 (BD Biosciences, San Jose, CA, USA); and CCR7-APCeFluor 780 (eBioscience, San Diego, CA, USA). Naïve and memory T cell subsets were defined by quadrant gating with FMO controls on a CD45RA versus CCR7 plot.
For cytokine staining, PBMCs were stimulated for 18–22 h at 37°C with overlapping peptide pools corresponding to HIV-1 Con B Gag peptides (NIH 8117) in the presence of 0.5 µg/mL Brefeldin A and 05 µg/mL Monensin (Sigma-Aldrich, St. Louis, MO, USA). A control well with no stimulation was run in parallel for each sample. Cells were washed and stained with AARD, fixed, and permeabilized for intracellular staining with antibodies against CD3-Pacific Blue, IFNγ-FITC, IL-2-PE (BD BioSciences), CD4-PE Texas Red, and CD8-QDOT 605 (Invitrogen). Data were compensated and analyzed using FlowJo V9 (TreeStar, Ashland, OR, USA).
+ Open protocol
+ Expand
2

Multiparametric Immune Cell Phenotyping

Check if the same lab product or an alternative is used in the 5 most similar protocols
Antibodies for surface staining included CCR7 APC-Cy7 (clone G043H7; Biolegend), CCR7 APC-eFluor780 (clone 3D12; eBioscience), CD4 PE-Cy5.5 (clone S3.5; Invitrogen), CD8 BV711 (clone RPA-T8; Biolegend), CD8 Qdot 605 (clone 3B5; Invitrogen), CD14 BV510 (clone M5E2; Biolegend), CD14 Pacific Blue (clone M5E2; custom), CD14 PE-Cy5 (clone 61D3; Abcam), CD14 PE-Cy7 (clone HCD14; Biolegend), CD16 Pacific Blue (clone 3G8; custom), CD16 PE-Cy5 (clone 3G8; Biolegend), CD16 PE-Cy7 (clone 3G8; Biolegend), CD19 BV510 (clone HIB19; Biolegend), CD19 Pacific Blue (clone HIB19; custom), CD19 PE-Cy5 (clone HIB19; Biolegend), CD19 PE-Cy7 (clone HIB19; Invitrogen), CD45RO ECD (clone UCHL1; Beckman Coulter), CD45RO PE-CF594 (clone UCHL1; BD Biosciences), CD107a PE-Cy5 (clone eBioH4A3; eBioscience), CD107a PE-Cy7 (clone H4A3; Biolegend), and HLA-DR Pacific Blue (clone LN3; Invitrogen). Antibodies for intracellular staining included CD3 BV570 (clone UCHT1; Biolegend), CD3 BV650 (clone OKT3; Biolegend), CD3 Qdot 585 (clone OKT3; custom), CD3 Qdot 650 (clone S4.1; Invitrogen), Eomes Alexa 647 (WD1928; eBioscience), Eomes eFluor 660 (WD1928; eBioscience), IFN-γ Alexa 700 (clone B27; Invitrogen), Perforin BV421 (clone B-D48, Biolegend), Perforin Pacific Blue (clone B-D48; custom), Perforin PE (clone B-D48, Cell Sciences), T-bet FITC (clone 4B10; Biolegend), and T-bet PE (clone 4B10; eBioscience).
+ Open protocol
+ Expand
3

Comprehensive Immune Phenotyping of PBMC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Immune activation and differentiation were quantified as previously described [54] (link). In brief, one million thawed PBMC were stained with either an activation or differentiation panel for 15 minutes at 37°C prior to fixation in formaldehyde. Both panels included CD3 V450 (Becton Dickinson); CD4 PE-Texas Red (Invitrogen); CD8 Qdot605 (Invitrogen). Activation panel included HLA-DR FITC; PD-1 AF647; CD38 PE; CCR5 PE-Cy5; 45RA PE-Cy7 (all Becton Dickinson); CCR7 APC eFluor-780 (eBioscience). Differentiation panel included CD45RA PE; CD28 PE-Cy5; CCR7 PE-Cy7; CD31 FITC (all Becton Dickinson); CD57 AF647 (Biolegend); CD27 AF780 (eBioscience). For Tregs, PBMC were surface stained with CD4 PerCP, CD127 PE and CD25 FITC (all Becton Dickinson) followed by intracellular staining using eBioscience FoxP3 staining kit and FoxP3 APC as per manufacturer's instructions. Data was acquired on a BD LSR-Fortessa and analysed using FlowJo version 10.
+ Open protocol
+ Expand
4

Multiparametric Flow Cytometry of Immune Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
For cell surface markers, cells were stained in PBS containing 2% fetal bovine serum for 15 minutes, unless mentioned otherwise. For intracellular cytokine staining, cells were stimulated with phorbol 12-myristate acetate (PMA) (50 ng/ mL) and ionomycin (1 lg/mL), or with different antigens, the last 8 hours with 10 lg/mL Brefeldin A and/or 2 lmol/mL monensin, at 378C and 5% CO 2 as mentioned above, and then fixed and stained according to manufacturer's protocols. Antibodies used were as follows: CD3-Alexa Fluor 700, CD4-PerCP/Cy5.5A, IFN-c Alexa Fluor 488, IL-17-PerCP/Cy5.5A, CCR7-APCeFluor780 (eBioscience, San Diego, CA, USA), CD8-V500A (Tonbo, San Diego, CA, USA), TNF-a-Alexa Fluor 700(BD), CD45RA-PECy7, CD45RO-PECF594, FAS-PECF594 (BD, San Diego, CA, USA), FasL-PE (Invitrogen), AnnexinV-APC (Immuno Tools, GmbH, Germany). Cells were acquired and analyzed by BD LSR Fortessa II (BD), using FlowJo (Ashland, OR, USA) three-star or FACSDIVA 6 software (BD Biosciences, San Jose, CA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!