The largest database of trusted experimental protocols

Milliplex map mouse cytokine chemokine magnetic bead panel mcytmag 70 k px32

Manufactured by Merck Group

The MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70 K-PX32) is a multiplex assay designed to detect and quantify multiple mouse cytokines and chemokines simultaneously in a single well. The panel utilizes magnetic beads coated with specific capture antibodies to measure the concentration of target analytes in a sample.

Automatically generated - may contain errors

Lab products found in correlation

6 protocols using milliplex map mouse cytokine chemokine magnetic bead panel mcytmag 70 k px32

1

Multiplex Cytokine Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Circulating cytokines were measured using 100μl of plasma and a MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70K-PX32, Millipore) that measures 32 cytokines/chemokines from limited samples. TGFβ1, 2 and 3 were measured separately. Each group contained plasma samples from six animals. Those samples with no detectable values were given a score of zero for the analyses.
+ Open protocol
+ Expand
2

Multiplex Cytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Circulating cytokines and chemokines were profiled and analyzed as described previously.9 (link),10 (link) Briefly, circulating cytokines were measured using 100 μL plasma and a MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70K-PX32; Millipore) that measures 32 cytokines/chemokines from limited samples. TGF-β1, TGF-β2, and TGF-β3 were measured separately. Each group contained plasma samples from nine animals. Those samples with no detectable values were given a score of zero for the analyses.
+ Open protocol
+ Expand
3

Cytokine and Chemokine Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cytokine and chemokine levels were measured in mouse serum (20× diluted) and brain samples (10× diluted) using the MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70 K-PX32; Millipore), following the manufacturer's instructions.
+ Open protocol
+ Expand
4

Comprehensive Cytokine and Chemokine Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cytokine and chemokine levels were measured in mouse serum (20× diluted) and brain samples (10× diluted) using the MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70 K-PX32; Millipore). Cytokine and chemokine levels were measured in human cell culture supernatants using the Human Cytokine Magnetic 30-Plex Panel for the Luminex platform (Life Technologies, Frederick, MD). All measurements were performed using a MAGPIX instrument (Luminex, Austin, TX), following the manufacturer’s instructions. Data were collected using xPonent software (Luminex), log transformed, and analyzed as described below.
+ Open protocol
+ Expand
5

Cytokine and Chemokine Profiling in Colon Tissue

Check if the same lab product or an alternative is used in the 5 most similar protocols
Colon tissues were harvested at the time of sacrifice and assessed using a 32-analyte MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70K-PX32, EMD Millipore, Billerica, MA) with a FLEXMAP 3D instrument (Luminex, Austin, TX) 10 (link), 18 (link), 19 , 37 (link), 45 (link). Data were standardized to tissue protein concentrations measured by the bicinchoninic acid (BCA) Protein Assay Kit (Pierce, Rockford, IL) 10 (link), 18 (link), 19 , 37 (link), 45 (link).
+ Open protocol
+ Expand
6

Cytokine and Chemokine Profiling in Colon Tissue

Check if the same lab product or an alternative is used in the 5 most similar protocols
Colon tissues were harvested at the time of sacrifice and assessed using a 32-analyte MILLIPLEX MAP Mouse Cytokine/Chemokine Magnetic Bead Panel (MCYTMAG-70K-PX32, EMD Millipore, Billerica, MA) with a FLEXMAP 3D instrument (Luminex, Austin, TX) 10 (link), 18 (link), 19 , 37 (link), 45 (link). Data were standardized to tissue protein concentrations measured by the bicinchoninic acid (BCA) Protein Assay Kit (Pierce, Rockford, IL) 10 (link), 18 (link), 19 , 37 (link), 45 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!