The largest database of trusted experimental protocols

Triglyceride quantification colorimetric fluorometric kit

Manufactured by Nanjing Jiancheng

The Triglyceride Quantification Colorimetric/Fluorometric Kit is a laboratory equipment product that provides a method for the quantitative determination of triglyceride levels in various samples. The kit utilizes either a colorimetric or fluorometric detection principle to measure the concentration of triglycerides present in the sample.

Automatically generated - may contain errors

2 protocols using triglyceride quantification colorimetric fluorometric kit

1

Quantification of Fly Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
For triglyceride and glycogen, a single fly was anesthetized and transferred to tube with the corresponding extract. The samples were measured according to the manufacturer’s instructions. Glycogen was measured with Liver/Muscle glycogen assay kit (#A043-1-1, Nanjing Jiancheng Bioengineering Institute, China). Triglyceride was measured with Triglyceride Quantification Colorimetric/Fluorometric Kit (#A110-1-1, Nanjing Jiancheng Bioengineering Institute).
The hemolymph trehalose was quantified by trehalose quantification kit (#A149-1-1, Nanjing Jiancheng Bioengineering Institute). Briefly, 40 flies were anesthetized and then pierced in the thorax with dissecting forceps. The pierced flies were then transferred to perforated tubes and centrifuged for 5 min at 3000×g at 4°C to collect the hemolymph. Afterward, 0.6 μL hemolymph was quickly removed into a 200 μL tube with trehalose extract and vortexed for 2–3 min. After 45 min standing, the sample was centrifuged at 8000×g for 10 min. Then 175 μL supernatant was added to 700 μL reaction solution and boiled for 5 min. After cooling, 250 μL sample was removed to a 96-well plate for the light absorption value measurement at 620 nm.
+ Open protocol
+ Expand
2

Quantification of Fly Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
For triglyceride and glycogen, a single fly was anesthetized and transferred to tube with the corresponding extract. The samples were measured according to the manufacturer’s instructions. Glycogen was measured with Liver/Muscle glycogen assay kit (#A043-1-1, Nanjing Jiancheng Bioengineering Institute, China). Triglyceride was measured with Triglyceride Quantification Colorimetric/Fluorometric Kit (#A110-1-1, Nanjing Jiancheng Bioengineering Institute).
The hemolymph trehalose was quantified by trehalose quantification kit (#A149-1-1, Nanjing Jiancheng Bioengineering Institute). Briefly, 40 flies were anesthetized and then pierced in the thorax with dissecting forceps. The pierced flies were then transferred to perforated tubes and centrifuged for 5 min at 3000×g at 4°C to collect the hemolymph. Afterward, 0.6 μL hemolymph was quickly removed into a 200 μL tube with trehalose extract and vortexed for 2–3 min. After 45 min standing, the sample was centrifuged at 8000×g for 10 min. Then 175 μL supernatant was added to 700 μL reaction solution and boiled for 5 min. After cooling, 250 μL sample was removed to a 96-well plate for the light absorption value measurement at 620 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!