Modular p800 automatic analyzer

Manufactured by Roche
Sourced in Germany, Switzerland

The Modular P800 is an automatic analyzer designed for clinical chemistry and immunoassay testing. It utilizes modular architecture to provide flexibility and scalability in laboratory workflows.

Automatically generated - may contain errors

3 protocols using modular p800 automatic analyzer

1

Measuring Serum FGF23, Phosphorus, and Calcium

Check if the same lab product or an alternative is used in the 5 most similar protocols
In sera of all rats from the two experiments, intact FGF23 concentration was measured by ELISA (Kainos Laboratories, Tokyo, Japan) as described in Heijboer et al [29 (link)]. Serum inorganic phosphorus and calcium were analyzed using a Modular P800 automatic analyzer (Roche, Mannheim, Germany).
+ Open protocol
+ Expand
2

Comprehensive Metabolic Biomarker Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma glucose was measured in the laboratory of Turku PET Centre in duplicate using the glucose oxidase technique (Analox GM7 or GM9, Analox Instruments Ltd., London, UK). Glycosylated hemoglobin (HbA1c) was measured with ion-exchange high performance liquid chromatography (Variant II Haemoglobin A1c, Bio-Rad Laboratories, CA, USA). Plasma insulin was determined by time-resolved immunofluorometric assay (AutoDELFIA, Perkin Elmer Inc, Wallac Oy, Turku, Finland). Serum FFA were measured with a photometric enzymatic assay (Wako Chemicals GmbH, Neuss, Germany) on Modular P800 automatic analyzer (Roche Diagnostics, Mannheim, Germany). Serum high-sensitivity C-reactive protein (hs-CRP) was analysed with the sandwich immunoassay method using an Innotrac Aio1 immunoanalyzer (Innotrac Diagnostics, Turku Finland). Serum adipokines were analysed in duplicate by using Milliplex Human Serum Adipokine (Panel A) kit [cat.no HADK1-61K-A] (MilliporeSigma, Burlington, MA, USA) containing interleukin-6 (IL-6), interleukin-8 (IL-8), tumor necrosis factor alpha (TNFα), and leptin.
+ Open protocol
+ Expand
3

Arterial Blood Sampling and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Arterial blood samples (0.5 mL) were drawn from the femoral artery at baseline, R15, and R90. The same volume of balanced colloid solution (VOLUVEN, Fresenius Kabi, Bad Homburg, Germany), was infused to correct for the very mild transient hypovolemia. Blood gas values, hemoglobin concentration, hemoglobin oxygen saturation, and acid-base balance were determined directly after sampling (ABL 505 blood gas analyzer, Radiometer, Copenhagen, Denmark).
Plasma lactate levels were assayed in samples acquired at baseline and at R90 by an enzymatic colorimetric method (modular P800 automatic analyzer, Roche Diagnostics, Basel, Switzerland).
It should be noted that urine-based kidney function parameters (urine production, creatinine clearance rate / glomerular filtration rate, and renal sodium reabsorption [58 ]) could not be determined because of I/R-induced anuria in all groups.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!