The largest database of trusted experimental protocols

4 protocols using 4 methylbenzenethiol

1

Alkylation of C20 uPAO Dimer with 4-Methylbenzenethiol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

A C20 uPAO dimer was alkylated with 4-methylbenzenethiol (obtained from Sigma-Aldrich) by acid catalyst as shown below in Scheme 2 to form Product II containing Compound-III and Compound-IV.

[Figure (not displayed)]

A glass reactor under N2 atmosphere was charged with C20 uPAO dimer (1001.12 g, 3.57 mol), 4-methylbenzenethiol (500.10 g, 4.02 mol) (obtained from Sigma-Aldrich), and Amberlyst 15-H (20.0 g, 1.31 wt %) (obtained from Sigma-Aldrich) to form a mixture. The mixture was heated with stirring at 120° C. for 3 days. The reaction mixture was filtered through Celite to remove catalyst. The filtrate was distilled under vacuum to 140° C. to remove unreacted thiol and then to 215° C. to remove unreacted olefin. The distillation pot bottoms were treated with decolorizing carbon (20 g) and filtered through Celite. The filtrate was collected as Product II containing Compound-III and Compound-IV. The lube properties of Product II were determined as provided above and are shown below in TABLE VI.

TABLE VI
Lube Properties
KV100 (cSt)4.16
KV40 (cSt)23.27
VI63
Pour Point (° C.)−61

+ Open protocol
+ Expand
2

Synthesis and Characterization of C16 uPAO Dimer Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 1

A C16 uPAO dimer was alkylated with 4-methylbenzenethiol by acid catalyst as shown below in Scheme 1 to form Product I containing Compound-I and Compound-II.

[Figure (not displayed)]

A glass reactor under N2 atmosphere was charged with C16 uPAO dimer (242.1 g, 1.07 mol), 4-methylbenzenethiol (160.4 g, 1.29 mol) (obtained from Sigma-Aldrich), and Amberlyst-15H (6.89 g, 1.7 wt %) (obtained from Sigma-Aldrich) to form a mixture. The mixture was heated with stirring at 120° C. for 20 hours. The mixture was filtered to remove catalyst. The filtrate was distilled under vacuum to 160° C.-205° C. to remove unreacted olefin and thiol. The distillation pot bottoms were collected as Product I containing Compound-I and Compound-II in a molar ratio of approximately 97.5 to 2.5. The lube properties of Product I were determined as provided above and are shown below in TABLE IV.

TABLE IV
Lube Properties
KV100 (cSt)3.151
KV40 (cSt)16.40
VI11
Noack volatility (%)21.56
HPDSC249.61

+ Open protocol
+ Expand
3

Lanthanide-doped Nanoparticle Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used without further purification. Gd2O3 (99.999%), Yb2O3 (99.999%), Y2O3 (99.999%) and Er2O3 (99.999%) were purchased from Chemicals 101 Corp. Sodium trifluoroacetate (98%) and 4-(trifluoromethyl)thiophenol (97%) were purchased from Alfa Aesar. Oleic Acid (90%), 1-octadecene (90%), IR820 (80%), 4-mercaptobenzoic acid (99%), 4-nitrothiophenol (80%), 4-methylbenzenethiol (98%) and sodium azide (99.5%) were purchased from Sigma Aldrich. HCl (trace metal grade, 99.999%) was purchased from Fisher Scientific. Transmission electron microscopy grids (FCF300-CU) were purchased from Electron Microscopy Sciences Inc. For MALDI-MS analysis, 2,5-dihydroxybenzoic acid (DHB), was purchased from Sigma-Aldrich and used without further purification. Liquid chromatography grade solvents were purchased from VWR. ESI-MS low concentration tuning mix was purchased from Agilent Technologies.
+ Open protocol
+ Expand
4

Synthesis of Aromatic Thioethers

Check if the same lab product or an alternative is used in the 5 most similar protocols
With exception of DMSO and THF all solvents were from Fisher Scientific; DMSO, THF, Et3N, CuI, NH4OAc, propanedinitrile, 4-aminobenzenethiol, and 4-methylbenzenethiol were from Sigma Aldrich. 1-Iodo-2-trifluoromethylbenzene was from Alfa Aesar, K2CO3 was from EM Scientific, CDCl3 was from Cambridge isotope laboratories Inc, and DMSO-d6 and CD3OD were from Acros Organics. The deionized water used was obtained from a Millipore Milli-Q Plus Ultra-Pure Water System.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.