The largest database of trusted experimental protocols

Agilent 1100 binary pump instrument

Manufactured by Agilent Technologies
Sourced in Italy

The Agilent 1100 binary pump is a liquid chromatography instrument designed to deliver precise and reliable solvent flow for analytical applications. It features two independent solvent delivery systems that can be used to create binary gradients for separation and purification of compounds. The instrument is capable of generating flow rates up to 10 mL/min and operating at pressures up to 400 bar.

Automatically generated - may contain errors

2 protocols using agilent 1100 binary pump instrument

1

Analysis of Organic Compounds by UV-Vis, NMR, and LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultraviolet–visible (UV–Vis) spectra were recorded on a Jasco V-730 spectrophotometer (Lecco, Italy).
Nuclear magnetic resonance (NMR) spectra were recorded at 400 MHz on a Bruker instrument (Milan, Italy).
HPLC analyses were performed on an Agilent 1100 binary pump instrument (Agilent Technologies, Milan, Italy) equipped with a UV–Vis detector, using an octadecylsilane-coated column, 250 mm × 4.6 mm, 5 µm particle size (Phenomenex SphereClone ODS, Bologna, Italy) at 0.7 mL/min, and the following gradient: 0.1% formic acid (eluent a)/methanol (eluent b): 40% b, 0–10 min; from 40 to 80% b, 10–47.5 min. The detection wavelength was set at 280 nm.
Liquid chromatography–mass spectrometry (LC–MS) analysis was performed on an HPLC 1100 VL series instrument (Agilent Technologies) with an electrospray ionization source in positive ion mode (ESI+). An Agilent Eclipse XDB-C18, 150 mm × 4.60 mm, 5 µm (Agilent Technologies) was used, with the same eluent used for the HPLC analysis at a flow rate of 0.4 mL/min. Mass spectra were registered under the following conditions: nebulizer pressure 50 psi; drying gas (nitrogen) flow 10 L/min, at 350 °C; and capillary voltage 4000 V.
+ Open protocol
+ Expand
2

Antioxidant Potential of Melanin-like Pigments

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gelatin type A from porcine skin (gel strength ~300 g bloom), 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium-chloride (DMTMM), chitosan, glacial acetic acid, 2,2-diphenyl-1-picrilhydrazyl (DPPH), ferric chloride (III) hexahydrate, and 2,4,6-tris(2-pyridyl)-s-triazine (TPTZ) were purchased from Sigma Aldrich (Milano, Italy) and used without any further purification. Phosphate buffer saline (PBS) 10× was purchased from VWR. DHICA and MeDHICA were prepared according to a procedure previously developed [36 (link),37 (link)].
The UV–Vis spectra were recorded on a Jasco V-730 Spectrophotometer (Lecco, Italy).
HPLC analyses were performed on an Agilent 1100 binary pump instrument (Agilent Technologies, Milan, Italy) equipped with a SPD-10AV VP UV–visible detector using an octadecylsilane-coated column, 250 mm × 4.6 mm, 5 μm particle size (Phenomenex Sphereclone ODS, Bologna, Italy) at 0.7 mL/min. Detection wavelength was set at 300 nm. Eluant system: 1% formic acid:acetonitrile, 85:15 v/v.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required