Prostar hplc 218 system

Manufactured by Agilent Technologies

The ProStar HPLC 218 system is a high-performance liquid chromatography (HPLC) instrument designed for analytical and preparative applications. It features a modular design, allowing for customization to meet specific research or laboratory requirements. The system includes a solvent delivery module, an autosampler, a UV-Vis detector, and a data management system.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using prostar hplc 218 system

1

Quantifying Mucoricin-Mediated RNA Depurination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The depurination activity of mucoricin was measured by the release of adenine when mammalian RNA was treated with mucoricin for 24 h at 37oC32 (link). Mammalian RNA extracted from A549 alveolar epithelial cells by Qiagen RNasy mini kits according to manufacturer’s instruction were treated with 20 μg/ml of mucoricin in 0.01M HEPES/10 mM ammonium acetate buffer containing 1 mg/ml BSA for 24 h at 37oC. The solution was then filtered through a 10 kDa size exclusion column and 40 μl was injected into HPLC using Phenomenex Luna C18 reverse phase column (10 × 250 mm) attached to a Varian ProStar HPLC 218 system (Varian, Walnut Creek, CA). Solvent A was 20 mM ammonium acetate, and solvent B was 100% acetonitrile. The column gradient was as follows: 97% to 60% solvent A in 10 min at flow rate of 1 ml/min. The column effluent was monitored at 260 nm.
+ Open protocol
+ Expand
2

Quantifying Mucoricin-Mediated RNA Depurination

Check if the same lab product or an alternative is used in the 5 most similar protocols
The depurination activity of mucoricin was measured by the release of adenine when mammalian RNA was treated with mucoricin for 24 h at 37oC32 (link). Mammalian RNA extracted from A549 alveolar epithelial cells by Qiagen RNasy mini kits according to manufacturer’s instruction were treated with 20 μg/ml of mucoricin in 0.01M HEPES/10 mM ammonium acetate buffer containing 1 mg/ml BSA for 24 h at 37oC. The solution was then filtered through a 10 kDa size exclusion column and 40 μl was injected into HPLC using Phenomenex Luna C18 reverse phase column (10 × 250 mm) attached to a Varian ProStar HPLC 218 system (Varian, Walnut Creek, CA). Solvent A was 20 mM ammonium acetate, and solvent B was 100% acetonitrile. The column gradient was as follows: 97% to 60% solvent A in 10 min at flow rate of 1 ml/min. The column effluent was monitored at 260 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!