Agilent1290 infinity 2d lc system

Manufactured by Agilent Technologies
Sourced in Germany

The Agilent 1290 Infinity 2D-LC system is a comprehensive two-dimensional liquid chromatography system designed for advanced sample analysis. It combines two chromatographic dimensions to deliver enhanced separation and identification capabilities. The system features precise solvent delivery, high-speed data acquisition, and seamless integration with Agilent's software platforms.

Automatically generated - may contain errors

2 protocols using agilent1290 infinity 2d lc system

1

Two-Dimensional Liquid Chromatography-Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two-dimensional LC
× LC–HRMS experiments were performed using an Agilent
1290 Infinity 2D- LC system (Agilent Technologies, Waldbronn, Germany)
coupled with a Waters Synapt-G2 high-resolution mass spectrometer.
The system comprised two binary pumps (G4220A) for solvent delivery,
an autosampler (G4226A), column thermostat (G1316C) equipped with
a 2D-LC 8-port 2-postion modulation valve (G4236A) with 40 μL
loops, and a diode-array detector (G4212A) equipped with an Agilent
Max-Light cartridge flow cell (G4212–6008, 10 mm, Vdet = 1.0 μL). The 1D column was a Phenomenex
Luna HILIC (150 × 2.0 mm i.d., 3.0 μm particles, 200 Å
pore size) column used for gradient-NPLC, while two Waters Acquity
APC XT columns (75 × 4.6 mm i.d., 1.7 μm particles, 45
Å pore size and 75 × 4.6 mm i.d., 2.5 μm particles,
125 Å pore size, respectively) were coupled in series for SEC
experiments.
For parallel UV/HRMS detection, the analytical
effluent was split after the second-dimension SEC column set using
a tee piece and in-house-made restriction capillaries (450 ×
0.075 mm i.d. and 900 × 0.050 mm i.d. capillaries), ensuring
a split ratio of 9:1 to the diode array and mass spectrometer, respectively.
Using the diverter valve of the Synapt-G2 system, the smallest split
flow was combined with a make-up flow (1:1 ratio) consisting of 1
mM NaI with 0.5% (v/v) 3-nitrobenzyl alcohol in deionized water.
+ Open protocol
+ Expand
2

Agilent 2D-LC System for Aromatic Amine Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
An Agilent 1290 Infinity 2D-LC system (Agilent, Santa Clara, CA) was used for all experiments in this study.
The system was comprised of an Infinity 1290 quaternary pump (G4204A), an Infinity 1290 autosampler (G4226A), an Infinity 1290 thermostatted column compartment (G1316C), and 1260 diode-array detector with a high-pressure flow cell (G1315C, 400 bar, 6mm pathlength, 1. Approximately 50 mL of an aromatic amine oligomer sample was obtained in-house from the Dow Chemical Company. The sample was diluted in N, N-dimethylformamide (DMF) (Fisher Chemical) roughly 10 times and then filtered with 0.2 µm PFTE filter (Fisher Brand, 25 mm syringe filter, 09-719 G). 2 µL of the filtered solution was injection for LC run.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!