Annexin 5 apc 7 aad kit

Manufactured by BD
Sourced in United States

The Annexin V-APC/7-AAD kit is a laboratory reagent used to detect and quantify apoptosis, or programmed cell death, in cell samples. The kit contains Annexin V conjugated to the fluorescent dye allophycocyanin (APC) and the DNA-binding dye 7-Aminoactinomycin D (7-AAD). These reagents allow for the identification of early and late apoptotic cells through flow cytometry analysis.

Automatically generated - may contain errors

4 protocols using annexin 5 apc 7 aad kit

1

Apoptosis Quantification by Flow Cytometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were harvested and stained using the Annexin V-APC/7-AAD kit (BD Biosciences, San Jose, CA, USA) for quantification of cell apoptosis according to the manufacturer's protocol. Cell detection and data analysis were performed on a fluorescent activated cell sorting caliber flow cytometer (FACScan; BD Biosciences) with CellQuest Pro software (version 5.1; BD Biosciences).
+ Open protocol
+ Expand
2

Apoptosis Detection via Flow Cytometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
The apoptosis rate was detected using the Annexin V-APC/7-AAD kit (BD, USA). Cells were exposed to 6 MV-X ray at doses of 0 and 4 Gy, and all cells in each group were collected 48 h after irradiation. Then, the cells were labelled with 5 μL Annexin V-APC and 5 μL 7-AAD according to the manufacturer’s instructions. Apoptotic cells were analyzed by the flow cytometry system (BD FACSCalibur, USA) within 1 h.
+ Open protocol
+ Expand
3

Curcumin and GAMCLCL Modulate HepG2 Apoptosis

Check if the same lab product or an alternative is used in the 5 most similar protocols
HepG2 cells (5 × 105cells/well) were seeded in 6-well plates with 1640 medium. After incubated overnight at 37 °C and in an atmosphere of 5% CO2, the medium was removed, the cells were washed twice with PBS, and the following treatments were applied: blank group, only 1640 medium was added; Curcumin group, 1640 medium containing 10 μg/mL curcumin was added; GAMCLCL group, 1640 medium containing GAMCLCL (equivalent to containing 10 μg/mL curcumin) was added. After incubation for 24 hours, the medium was removed, and the cells were carefully washed twice with PBS. After digestion with 0.25% trypsin without EDTA, the cells were centrifuged for 5 min at 1200 rpm and harvested. The AnnexinV-APC/7-AAD kit (KGA1026, Nanjing, China) was used for the flow cytometry (BD Biosciences, USA) evaluation of apoptosis.
+ Open protocol
+ Expand
4

Annexin V-APC/7-AAD Cell Apoptosis Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
According to the instructions of the manufacturer, Annexin V-APC/7-AAD kit (BD Pharmingen, San Diego, CA, USA) was used to detect cell apoptosis. SW1353 and C28/I2 cells were treated as above. Subsequently, cells from different treatment groups were resuspended in 500 μL of 1 × binding buffer, stained with Annexin V-APC (5 μL) and 7-AAD (5 μL) for 15 min in the dark, respectively, and then examined using a flow cytometer (Beckman Coulter, CA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!