The largest database of trusted experimental protocols

Immunocap isac technology

Manufactured by Thermo Fisher Scientific
Sourced in Sweden

The ImmunoCAP ISAC technology is a laboratory equipment used for allergy testing. It provides a comprehensive analysis of a patient's IgE reactivity to a broad panel of allergens. The technology utilizes a microarray-based approach to measure the levels of specific IgE antibodies in a patient's blood sample.

Automatically generated - may contain errors

2 protocols using immunocap isac technology

1

Allergen-Specific IgE and IgG Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
IgE and IgG reactivity to 174 allergen molecules (Table S2), was determined, using MeDALL allergen chips, which had been produced according to ImmunoCAP ISAC technology (Thermofisher), as described previously.24 For IgG measurements samples were diluted 1:50 using sample diluent (Thermofisher).
Bound IgE or IgG antibodies, were determined by scanning chips using LuxScan 10K micro‐array Scanner (CapitalBio Technology). The analysis of scanned chips was performed with the micro‐array evaluation software version 3.1.2 (customized for MeDALL chips). Results were summarized in three categories for specific IgE/IgG values (0.1 < ISU < 1, 1 < ISU < 15, and >15 ISAC Standardized Units) (ISU). Patients having antibody levels above 0.1 ISU were considered positive. Subjects displaying IgE reactivity to any of the allergens on the MeDALL chip were considered as having an IgE sensitization.
+ Open protocol
+ Expand
2

Multiplex IgE Measurement for Allergy

Check if the same lab product or an alternative is used in the 5 most similar protocols
MeDALL allergen chips which had been developed based on the ImmunoCAP ISAC technology (Thermofisher, Phadia, Uppsala, Sweden) as described were used for measurement of specific IgE in sera from both groups of children (Figure 1).36 Arrays were scanned using a LuxScan 10K Microarray Scanner (CapitalBio Technology, Beijing, China) and analyzed with the micro‐array evaluation software version 3.1.2. The specific IgE levels measured by the MeDALL chip correspond to specific IgE levels measured with ImmunoCAP® ISAC 112 and were standardized with a reference serum pool with known levels of specific IgE obtained from Thermofisher which is used as a reference serum pool (standard) in ImmunoCAP® ISAC 112. Results are given in ISU‐IgE (ISAC standardized units). According to previous studies, the threshold for positivity of allergen‐specific IgE was defined by an IgE level of = or > 0.3 ISU‐IgE. The MeDALL chip showed equal or even slightly superior sensitivity in direct comparison to ImmunoCAP due to low background signals and a sensitive, fluorescence‐based detection system.36 Intra‐assay variation was determined to be approximately 8% in the IgE range of 1‐130 ISU‐IgE.36
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!