The largest database of trusted experimental protocols

Msp anchorchip target plate

Manufactured by Bruker

The MSP AnchorChip target plate is a lab equipment product designed for use in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. The product provides a platform for sample preparation and analysis.

Automatically generated - may contain errors

3 protocols using msp anchorchip target plate

1

MALDI-TOF Analysis of Peptide Conjugation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Conjugation efficiency was determined using MALDI-TOF. Peptides were added to a saturated solution of α-cyano-4-hydroxycinnamic acid in 70% methanol, 0.05% TFA and dried onto the MSP AnchorChip target plate (Bruker) using the dried droplet method. The Bruker Microflex MALDI-TOF mass spectrometer was calibrated with the Bruker Peptide Calibration Standard II. Mass spectra were analyzed using FlexAnalysis software (https://researchservices.pitt.edu/sites/default/files/flexAnalysis%20User%20Manual.pdf) (Bruker).
+ Open protocol
+ Expand
2

MALDI-TOF Analysis of Peptides

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peptides were added to a saturated solution of α-HCCA in 70% methanol with 0.05% TFA. The resulting solution was dried onto the MSP AnchorChip target plate (Bruker, Billerica, MA) using the dried droplet method (Karas and Hillenkamp, 1988 (link)). The Bruker Microflex MALDI-TOF mass spetrometer was calibrated with the Bruker Peptide Calibration Standard II (Billerica, MA). Mass spectra were analyzed using FlexAnalysis software (Bruker, Billerica, MA).
+ Open protocol
+ Expand
3

MALDI-TOF Mass Spectrometry of Peptides

Check if the same lab product or an alternative is used in the 5 most similar protocols
For matrix-assisted laser desorption ionization time of flight (MADLI-TOF) mass spectrometry measurements, peptide in solvent was mixed with a saturated solution of a-cyano-4-hydroxycinnamic acid (a-HCCA) in a mixture of 70% methanol and 0.05% trifluoroacetic acid. This solution was dried dropwise onto an MSP AnchorChip target plate (Bruker, Billerica, MA). Mass spectra were collected on a Bruker Microflex MALDI-TOF mass spectrometer, calibrated with the Bruker Peptide Calibration Standard II (Billerica, MA). Spectra were analyzed using FlexAnalysis software (Bruker, Billerica, MA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!