1 ethyl 3 3 dimethylaminopropyl carbodiimide edc
1-Ethyl-3-(3'-dimethylaminopropyl)carbodiimide (EDC) is a water-soluble carbodiimide reagent commonly used in various chemical coupling reactions, particularly in peptide synthesis and protein modification applications.
Lab products found in correlation
7 protocols using 1 ethyl 3 3 dimethylaminopropyl carbodiimide edc
Chitosan-based hydrogel synthesis
Synthesis and Characterization of Furfurylated Gelatin
was synthesized and characterized as previously reported.28 (link) Porcine gelatin (4 g, Sigma-Aldrich) was dissolved
in 300 mL of milli-Q water. N-Hydroxysuccinimide
(NHS) (3.9 g, Tokyo Chemical Industry, Tokyo, Japan) and 1-ethyl-3-(3-(dimethylamino)propyl)carbodiimide
(EDC) (4.8 g, Tokyo Chemical Industry), dissolved in 100 mL of milli-Q
water, and furfurylamine (1.5 g, Sigma-Aldrich) were added slowly
to the gelatin solution, and then the solution was stirred at 40 °C
for 24 h. After the reaction, the solution was filtrated and then
dialyzed using a dialysis membrane with a molecular weight cutoff
of 3500 Da (Spectrum Laboratories, Rancho Dominguez, CA) against water
for 3 days in dark conditions. The f-gelatin was recovered by lyophilization
and was used for further studies.
Botulinum Toxin-Hyaluronate Conjugate Synthesis
Solid-Phase Peptide Synthesis Reagents
Biotin-Avidin Surface Functionalization
and EZ-Link NHS-PEG4-biotin were
purchased from Thermo Fisher Scientific (Waltham, MA). Biotinylated
DNA and fluorescent-tagged oligonucleotides were purchased from Eurofin
Genomics (Tokyo, Japan). Manicure was purchased from Shiseido (Tokyo,
Japan). 3-Aminopropyltriethoxysilane (APTES) was purchased from Sigma
Aldrich (St. Louis, MO). Boric acid was purchased from Nacalai Tesque
(Kyoto, Japan). 4-(2-Hydroxyethyl)-1-piperazineethanesulfonic acid
(HEPES) and ethylenediaminetetraacetic acid (EDTA) were purchased
from Dojindo (Kumamoto, Japan). A cover glass (18 mm × 18 mm,
no. 1S, 0.175 ± 0.015 mm thickness) and a slide glass (76 mm
× 26 mm, S-0314 Neo no. 2, 1.0–1.2 mm thickness) were
purchased from Matsunami Glass Industries (Osaka, Japan). 1-Ethyl-3-[3-dimethylaminopropyl]carbodiimide
(EDC) was purchased from Tokyo Chemical Industry (Tokyo, Japan). N-Hydroxysuccinimide (NHS) was purchased from Wako Pure
Chemical Industries (Osaka, Japan). All of the other reagents were
purchased from Wako Pure Chemical Industries, Ltd. (Osaka, Japan),
unless otherwise specified, and used without further purification.
Type 1 ultrapure water (Milli-Q) was used in all of the experiments.
Conjugation of DSPE-PEG-NH2 Polymer
Polycaprolactone-Chitosan-Gallic Acid Scaffold
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!