Advia 1650 system

Manufactured by Siemens
Sourced in Germany, United States

The ADVIA-1650 system is a clinical chemistry analyzer designed for routine diagnostic testing in medical laboratories. The system performs a range of biochemical assays to measure various analytes in patient samples. The core function of the ADVIA-1650 is to provide accurate and reliable laboratory results to support clinical decision-making.

Automatically generated - may contain errors

2 protocols using advia 1650 system

1

Lipid Profile Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All study participants were asked to fast for at least 8 h the day before blood collection. Between 8 a.m. and 10 a.m., a clinical pathologist collected 15 mL of blood from the participants’ forearms vein using a spasm blood collection tube and needle. The collected blood was then centrifuged at 3000 rpm for 10 min, using a Combi-514R (Hanil, Seoul, Republic of Korea), with the serum being used for analysis.
Total cholesterol (TC) and triglycerides (TGs) were analyzed via enzyme colorimetry using automatic analyzers and the contained reagents from Siemens (ADVIA-1650; Norcross, GA, USA). High-density lipoprotein (HDL) and low-density lipoprotein (LDL) cholesterol were also analyzed via the elimination/catalase method, using the ADVIA-1650 system (Siemens, Berlin, Germany) in accordance with the manufacturer instructions.
+ Open protocol
+ Expand
2

Serum Biochemistry and Endocrinology in Bearded Seals

Check if the same lab product or an alternative is used in the 5 most similar protocols
A total of 25 serum samples from four captive bearded seals and serum samples from 74 wild bearded seals were analysed for selected enzymes, proteins, metabolites, minerals, cortisol, and thyroxine (Table 1). Serum chemistry analyses were assayed using an ADVIA® 1650 System (Siemens Healthcare Diagnostics, USA). Lipaemia was indicated by the ADVIA 1650 System, and samples classified as lipaemic (1+ and 2+) were automatically diluted before analysis to avoid erroneous measurements [17 ]. Serum endocrinology analyses (cortisol and thyroxine) were assayed using an IMMULITE® 2000 Immunoassay System (Siemens Healthcare Diagnostics, USA). The reference values for serum biochemistry parameters and hormones were calculated in Excel and are presented as median, range (min–max) and percentiles (5–95%), to show variation and a reference range that is excluding outliers.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!