Agilent 1200 infinity system

Manufactured by Agilent Technologies
Sourced in Germany

The Agilent 1200 Infinity system is a high-performance liquid chromatography (HPLC) platform designed for analytical and preparative applications. It features advanced technology for reliable and efficient separation and detection of a wide range of analytes. The system includes modular components such as pumps, autosamplers, detectors, and columns, allowing for customization to meet specific laboratory requirements.

Automatically generated - may contain errors

5 protocols using agilent 1200 infinity system

1

HPLC Analysis of Steroid Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sample preparation: an aliquot of the culture liquid (0.25 mL) was diluted 10 times with a mixture of acetonitrile:isopropanol (50:45, v/v), mixed and centrifuged within 8 min at 12,100 × g. The supernatant was used for analysis. HPLC analyses were performed on an Agilent Infinity 1200 system (Agilent Technologies, Germany) with a Symmetry C18 column (4.6 × 250 mm, 5 μm) with a Symmetry C18 precolumn (3.9 × 20 mm, 5 μm,) (Waters, Milford, MA, USA) at 50 °C and a flow rate of 1 mL/min. Steroid assay was performed using two mobile phases: I—acetonitrile:2-propanol:water (50:45:5 (v/v/v)) and II—acetonitrile:water:TFA (60:40:0.02 (v/v/v)) with gradient elution as described [43 ], UV-detection at 200 (I) and 240 nm (II). Calibrations were performed by the external standard method based on peak areas. The results were processed using the ChemStation Rev. software. B.04.03 (Agilent Technologies, USA). Retention times (Rt) for mobile phase I: cholesterol, Rt 10.3; phytosterols, Rt 9.5–10; pregnenolone, Rt 3.16; for mobile phase II: progesterone, Rt 10.56. Rt of 3-methoxymethyl derivatives are given in Table 1.
+ Open protocol
+ Expand
2

HPLC Analysis of Steroid Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC analyses were performed using reversed-phase HPLC on an Agilent Infinity 1200 system (Agilent Technologies, Germany SA) with a Symmetry column (250 × 4.6 mm, 5 μm) with a Symmetry C18 precolumn (5 μm, 3.9 × 20 mm) (Waters, Milford, MA, USA) at 50 °C and a flow rate of 1 mL/min. Steroid assays were performed using two mobile phases (acetonitrile:water:acetic acid (60:40:0.01, v/v/v) and acetonitrile:2-propanol:water (50:45:5, v/v/v)) with UV-detection at 200 nm (for compounds with the 3β-ol-5-ene configuration) and 240 nm (for compounds with the 3-oxo-4-ene configuration).
+ Open protocol
+ Expand
3

Gradient HPLC Analysis of Phospholipids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analyses were performed with an Agilent 1200 infinity system (Agilent Technologies) using ELSD Sedex 100 and DAD (280 nm) detectors, an Agilent Zorbax Eclipse Plus C18 RRHD (2.1 × 50 mm, 1.8 μm) as the stationary phase, with a mobile phase composed of A = H2O and Na2HPO4 (10 mM), Na2B4O7 (10 mM), pH = 8.2 and B = MeOH:acetonitrile:H2O, 45:55:10 pH = 8.2 with a gradient from 98:2 to 0:100, over 13 min, 0.2 mL/min, column temperature: 40 °C, sample volume injection: 1 μL.
+ Open protocol
+ Expand
4

UPLC-ELSD/DAD Protocol for Polar Compound Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analyses were performed with an Agilent 1200 infinity system (Agilent Technologies (Les Ulis, France)) using ELSD Sedex 100 and DAD (280 nm) detectors, an Acquity UPLC BEH amide (2.1 × 100 mm, 1.7 μm) as the stationary phase, with a mobile phase composed of acetonitrile:H2O, 9:1 and NH4OH (10 mmol/L) with isocratic elution over 21 min, 0.2 mL/min, column temperature: 50 °C, sample volume injection: 1 μL.
+ Open protocol
+ Expand
5

UPLC-MS Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analyses were performed with an Agilent 1200 infinity system (Agilent Technologies) using ELSD Sedex 100 and DAD (280 nm) detectors, an Acquity UPLC BEH amide (2.1 × 100 mm, 1.7 μm) as the stationary phase, with a mobile phase composed of A = acetonitrile:H2O, 9:1 and NH4OH (10 mmol/L) and B = acetonitrile:H2O, 5:5 and NH4OH (10 mmol/L) with a gradient from 98:2 to 2:98, over 15 min, 0.5 mL/min, column temperature: 50 °C, sample volume injection: 1 μL.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!