The largest database of trusted experimental protocols

Dalton microtof q 2 spectrometer

Manufactured by Bruker
Sourced in United States

The Dalton micrOTOF-Q II spectrometer is a high-resolution mass spectrometer designed for accurate mass measurements. It utilizes quadrupole time-of-flight (Q-TOF) technology to provide precise mass analysis of a wide range of compounds.

Automatically generated - may contain errors

4 protocols using dalton microtof q 2 spectrometer

1

Synthesis of Novel Heterocyclic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemical reagents and solvents were purchased from Leyan-Shanghai Haohong Scientific Co., Ltd., Shanghai, China. Reactions were monitored by TLC plates coated with 0.25 mm silica gel 60 F254 and visualized by UV irradiation (254 nm). Flash column chromatography employed silica gel (particle size 32–63 μm, Qingdao Haiyang Chemicals, Qingdao, China). NMR spectra were acquired on an AV-400 instrument (Bruker BioSpin, Faellanden, Switzerland) with chemical shifts reported in ppm and referenced to CDCl3. IR spectra were obtained with a Vertex-70 instrument (Bruker Optics, Billerica, MA, USA). High-resolution mass spectra were obtained with a Dalton micrOTOF-Q II spectrometer (Bruker Optics, Billerica, MA, USA) and reported as m/z. Melting points were determined with an X-4 digital melting point apparatus and uncorrected (Tech Instrument, Beijing, China). The characterization data of known compounds 19, 11, and 1317 are in agreement with previous reports [17 (link),18 (link),20 (link),23 (link),32 (link),45 (link)] and listed in the Supplementary Materials. The characterization spectra of new compounds 10, 12, 1820 are also provided in the Supplementary Materials.
+ Open protocol
+ Expand
2

Synthetic Procedures and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
General chemical reagents and solvents were obtained from commercial suppliers. All reactions were monitored by thin layer chromatography on plates coated with 0.25 mm silica gel 60 F254 (Qingdao Haiyang Chemicals, Qingdao, China). TLC plates were visualized by UV irradiation (254 nm, Shanghai Peiqing Sci & Tech, Shanghai, China). Flash column chromatography employed silica gel (particle size 32–63 μm, Qingdao Haiyang Chemicals, Qingdao, China). Melting points were determined with a Thomas-Hoover melting point apparatus (Thomas Scientific, Swedesboro, NJ, USA) and uncorrected. NMR spectra were obtained with a Bruker AV-400 instrument (Bruker BioSpin, Faellanden, Switzerland) with chemical shifts reported in parts per million (ppm, δ) and referenced to CDCl3 or DMSO-d6. The NMR spectra of compounds 11, 15, 16, 2023, 25, and 2729 were provided in Supplementary Materials (Figures S1–S22). IR spectra were recorded on a Bruker Vertex-70 spectrometer (Bruker Optics, Billerica, MA, USA). High-resolution mass spectra were reported as m/z and obtained with a Dalton micrOTOF-Q II spectrometer (Bruker Daltonics, Billerica, MA, USA).
+ Open protocol
+ Expand
3

Synthesis and Purification of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were purchased from commercial sources and used without purification unless specified. Acetonitrile, pyridine and CH2Cl2 were refluxed with CaH2 and distilled prior to use. THF was dried with LiAlH4 and distilled prior to use. Thin-layer chromatography was performed using silica gel GF-254 plates (Qingdao Chemical Company, Qingdao) detected by UV (254 nm) or charting with 10% sulfuric acid in ethanol. Column chromatography was performed on silica gel (200–300 mesh, Qingdao Chemical Company, Qingdao). NMR spectra were recorded on a Bruker AV400 spectrometer. Chemical shifts (δ) are reported in ppm and coupling constants (J) are reported in Hz. Then, 1H and 13C NMR spectra were calibrated with TMS as an internal standard. The specific rotation was measured on a Rudolph autopol IV polarimeter. ESI-MS was acquired with a Bruker Dalton microTOFQ II spectrometer.
+ Open protocol
+ Expand
4

Synthesis of Novel Heterocyclic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemical reagents and solvents were purchased from Leyan-Shanghai Haohong Scientific Co. Ltd., Shanghai, China. Reactions were monitored by TLC plates coated with 0.25 mm silica gel 60 F254 and visualized by UV irradiation (254 nm). Flash column chromatography employed silica gel (particle size 32–63 μm, Qingdao Haiyang Chemicals, Qingdao, China). NMR spectra were acquired on an AV-400 instrument (Bruker BioSpin, Faellanden, Switzerland) with chemical shifts reported in ppm and referenced to CDCl3, DMSO-d6, or D2O. IR spectra were obtained with a Vertex-70 instrument (Bruker Optics, Billerica, MA, USA). High-resolution mass spectra were obtained with a Dalton micrOTOF-Q II spectrometer (Bruker Optics, Billerica, MA, USA) and reported as m/z. Melting points were determined with an X-4 digital melting point apparatus and uncorrected (Tech Instrument, Beijing, China). The characterization data of 1 and 913 and NMR spectra of all synthesized compounds are provided in the Supplementary Materials.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!