RP-HPLC Retention Time Profiling of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 57

Samples of compounds 19-38 were injected on an HPLC system equipped with an Phenomenex Luna C18(2) 5μ, 150×4.6 mm, 100 Å column and eluted with either a gradient of 10% MeCN (0.1% TFA)/90% water (0.1% TFA) to 90% MeCN (0.1% TFA)/10% water (0.1% TFA) or a gradient of 10% MeCN/90% 10 mM potassium phosphate buffer pH 7.4 to 90% MeCN/10% 10 mM potassium phosphate buffer pH 7.4. The retention times obtained for these compounds are depicted in Table 3.

Time Program:

  • 0-12 min: 10% MeCN to 90% MeCN
  • 12-14 min: 90% MeCN
  • 14-15 min: 90% MeCN to 10% MeCN
  • 15-17 min: 10% MeCN

TABLE 3
Retention times of compounds 19-23 and 30-38 on RP-HPLC.
retention time (min)
compound0.1% TFApH 7.4
19 (comp.)11.411.4
2011.69.6
2111.69.2
22 (comp.)12.712.6
2310.66.9
30 (comp.)10.510.6
31 (comp.)10.110.1
32 (comp.)9.79.7
3310.49.3
34 (comp.)11.511.5
3511.610.0
3610.49.3
3711.210.5
3811.19.5

+ Open protocol
+ Expand
2

High-Performance Liquid Chromatography Retention Times

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 57

Samples of compounds 19-38 were injected on an HPLC system equipped with an Phenomenex Luna C18(2) 5μ, 150×4.6 mm, 100 Å column and eluted with either a gradient of 10% MeCN (0.1% TFA)/90% water (0.1% TFA) to 90% MeCN (0.1% TFA)/10% water (0.1% TFA) or a gradient of 10% MeCN/90% 10 mM potassium phosphate buffer pH 7.4 to 90% MeCN/10% 10 mM potassium phosphate buffer pH 7.4. The retention times obtained for these compounds are depicted in Table 3.

Time Program:

    • 0-12 min: 10% MeCN to 90% MeCN
    • 12-14 min: 90% MeCN
    • 14-15 min: 90% MeCN to 10% MeCN
    • 15-17 min: 10% MeCN

TABLE 3
Retention times of compounds 19-23 and
30-38 on RP-HPLC.
retention time (min)
compound0.1% TFApH 7.4
19 (comp.)11.411.4
2011.69.6
2111.69.2
22 (comp.)12.712.6
2310.66.9
30 (comp.)10.510.6
31 (comp.)10.110.1
32 (comp.)9.79.7
3310.49.3
34 (comp.)11.511.5
3511.610.0
3610.49.3
3711.210.5
3811.19.5

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!