Oxford Diffraction Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▸ ) Tmin = 0.774, Tmax = 1.000
8463 measured reflections
2830 independent reflections
2506 reflections with I > 2σ(I)
Rint = 0.023
The Xcaliber Eos Gemini diffractometer is a laboratory instrument designed for X-ray diffraction analysis. It is used to identify and quantify the crystalline phases present in a sample. The instrument generates X-rays, which interact with the sample's crystal structure, and the resulting diffraction pattern is analyzed to provide information about the sample's composition and structure.
Oxford Diffraction Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▸ ) Tmin = 0.774, Tmax = 1.000
8463 measured reflections
2830 independent reflections
2506 reflections with I > 2σ(I)
Rint = 0.023
Oxford Diffraction Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▸ ) Tmin = 0.715, Tmax = 1.000
40860 measured reflections
4248 independent reflections
3956 reflections with I > 2σ(I)
Rint = 0.033
Oxford Diffraction Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▸ ) Tmin = 0.860, Tmax = 1.000
14591 measured reflections
2160 independent reflections
2044 reflections with I > 2σ(I)
Rint = 0.022
Oxford Diffraction Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▸ ) Tmin = 0.923, Tmax = 1.000
8119 measured reflections
2408 independent reflections
2187 reflections with I > 2σ(I)
Rint = 0.026
Oxford Diffraction Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▸ ) Tmin = 0.700, Tmax = 1.000
18486 measured reflections
2784 independent reflections
2616 reflections with I > 2σ(I)
Rint = 0.022
Agilent Xcaliber Eos Gemini diffractometer
Absorption correction: multi-scan (CrysAlis PRO; Agilent, 2011 ▶ ) Tmin = 0.80, Tmax = 0.96
5463 measured reflections
2460 independent reflections
2327 reflections with I > 2σ(I)
Rint = 0.022
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!
Notifications