The largest database of trusted experimental protocols

Electronic digital micrometer model co 030025

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Electronic Digital Micrometer Model CO-030025 is a precision measuring instrument designed for accurate measurements of small dimensions. It features a digital display and an electronic measuring system to provide precise readings. The device is capable of measuring linear dimensions with high accuracy.

Automatically generated - may contain errors

2 protocols using electronic digital micrometer model co 030025

1

Dynamic Flow System for Nitrile Glove Permeation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The assembled YDRH
(Figure 1) was part
of a closed-loop dynamic flow system that recirculated collection
Milli-Q water solvent by a peristaltic pump (Reglo 2-channel Var-Speed
Analog pump from Cole Parmer, Court Vernon Hills, IL) at 100 mL/min
between the inside surface of the test disposable nitrile glove and
the outside surface of the CPC Solvex powderless unsupported/unlined
nitrile glove (Ansell, Iselin, New Jersey) that protected the YDRH.10 (link),11 (link) The inlet and outlet of the YDRH were connected to the sampling
point by Viton tubing (2.79 mm inner diameter extension and three-stop,
Cole Parmer, Vernon Hill, IL). The hand in exposure situations was
immersed inverted, held by the wrist from a clamp, in limonene contained
in a vacuum desiccator (5-L from Fisher Scientific) within a Precision
Econotherm Laboratory Oven (Fisher Scientific) at 35 °C (Figure 1). The hand was powered
as described elsewhere to produce a 1.8 kg clenching force.8 (link),10 (link),11 (link) Thicknesses of the conditioned
and reconditioned gloves after each permeation experiment were measured
with an Electronic Digital Micrometer Model CO-030025 (0–25
mm, 0.001 mm resolution) from Fisher Scientific. Permeation experiments
were performed in triplicate.
+ Open protocol
+ Expand
2

Evaluating Nitrile Glove Performance

Check if the same lab product or an alternative is used in the 5 most similar protocols
Disposable purple nitrile exam gloves, powder-free, unlined, and unsupported with 24.2 cm
length and 0.12 mm thickness from Kimberly-Clark Professional, No. 55082-M were selected.
Both analytes, 2-EE and 2-BE with 99% purity, were ordered from Acros Organics.
For the analytical and instrumentational method, gas chromatography mass-spectrometry
(GC-MS) was applied with 4-bromophenol (99%) and Helium (99.999%) as the internal standard
(IS) and carrier gas respectively. The water used for all aqueous solutions passed through
two filtration systems, Millipore Milli-Q Water System and Millipore Ultrapure Water
Purification System as a finisher (Temecula, CA, USA).
An Electronic Digital Micrometer Model CO-030025 (0–25 mm, 0.001 mm resolution) from Fisher
Scientific was utilized to measure the glove thickness. In order to weigh the glove cuts, a
Mettler analytical balance AE260 Scale (Mettler, Hightstown, NJ, USA) was used. A water bath
with moving feature was applied to implement the temperature and solvent mixing adjustments
as modifications on four ASTM F739-12 permeation cells with 2.54 cm diameter, model
I-PTC-600 holding a challenge and collection chamber, aluminum and stainless-steel flanges,
Teflon gaskets, and bolts were obtained from Pesce Lab (Kennett Square, PA, USA). More
details about the GC–MS system analytical procedures and specifications are published in
another report12 (link)).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!