The Amicon Ultra 10K-15 mL centrifugal filter is a laboratory equipment device designed for sample concentration and buffer exchange. It utilizes a 10,000 molecular weight cutoff (MWCO) membrane to retain macromolecules such as proteins while allowing smaller molecules to pass through during centrifugation.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using amicon ultra 10k 15 ml centrifugal filter

1

IRDye700DX Labeling of P10-2 Fab

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 10

IRDye700DX NHS Ester (LI-COR Bioscience, Inc.) was used to label P10-2 Fab with IRDye700DX.

Specifically, a P10-2 Fab solution adjusted to 1 mg/mL with phosphate-buffered saline (pH 7.4) was supplemented with a 1/10 amount of a 1 M dipotassium hydrogen phosphate solution (pH 9). IRDye700DX NHS Ester was added thereto at a final concentration of 154 μg/mL, and the resultant was stirred at room temperature for 2 hours. After reaction, IRDye700DX-labeled P10-2 Fab was purified by recovery through Amicon Ultra 10K-15 mL centrifugal filter (Merck Millipore). This IRDye700DX-labeled P10-2 Fab was designated as P10-2 Fab IR700.

+ Open protocol
+ Expand
2

IRDye700DX Labeling of P10-2 Fab

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 10

IRDye700DX NHS Ester (LI-COR Bioscience, Inc.) was used to label P10-2 Fab with IRDye700DX.

Specifically, a P10-2 Fab solution adjusted to 1 mg/mL with phosphate-buffered saline (pH 7.4) was supplemented with a 1/10 amount of a 1 M dipotassium hydrogen phosphate solution (pH 9). IRDye700DX NHS Ester was added thereto at a final concentration of 154 μg/mL, and the resultant was stirred at room temperature for 2 hours. After reaction, IRDye700DX-labeled P10-2 Fab was purified by recovery through Amicon Ultra 10K-15 mL centrifugal filter (Merck Millipore). This IRDye700DX-labeled P10-2 Fab was designated as P10-2 Fab IR700.

+ Open protocol
+ Expand
3

Fluorescent Labeling of P10-2 Fab

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 10

IRDye700DX NHS Ester (LI-COR Bioscience, Inc.) was used to label P10-2 Fabwith IRDye700DX.

Specifically, a P10-2 Fab solution adjusted to 1 mg/mL with phosphate-buffered saline (pH 7.4) was supplemented with a 1/10 amount of a 1 M dipotassium hydrogen phosphate solution (pH 9). IRDye700DX NHS Ester was added thereto at a final concentration of 154 μg/mL, and the resultant was stirred at room temperature for 2 hours. After reaction, IRDye700DX-labeled P10-2 Fab was purified by recovery through Amicon Ultra 10K-15 mL centrifugal filter (Merck Millipore). This IRDye700DX-labeled P10-2 Fab was designated as P10-2 Fab IR700.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!