Pierce quantitative colorimetric or fluorescent peptide assay

Manufactured by Thermo Fisher Scientific

The Pierce Quantitative Colorimetric or Fluorescent Peptide Assay is a laboratory instrument designed to quantitatively measure the concentration of peptides in a sample. It utilizes either colorimetric or fluorescent detection methods to determine the peptide content.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using pierce quantitative colorimetric or fluorescent peptide assay

1

Peptide Quantification and LC-MS Sample Prep

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell pellets were thawed on ice and subjected to sample preparation with the PreOmics iST kit (PreOmics, Planegg, Germany) according to the manufacturer’s protocol. Samples were resuspended in LC-Load Buffer from the iST kit and peptide concentration determined (Pierce Quantitative Colorimetric or Fluorescent Peptide Assay, ThermoFisher Scientific, Waltham, Massachusetts). Sample concentration was normalized to 100 ng/μl and 2 μl was loaded onto the instrument.
+ Open protocol
+ Expand
2

Proteomics Sample Preparation and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sorted cells were pelleted and washed twice with ice-cold PBS to remove any remaining FBS (1,300 rpm x 5 min, 4°C). PBS was aspirated away, and the pellets were snap frozen with liquid nitrogen prior to storage at −80°C. Prior to lysis, cells were thawed on ice and subjected to sample preparation with the PreOmics iST NHS kit (PreOmics, Planegg, Germany) according to literature protocol. (To normalize lysis across cell number, 10 μL of lysis buffer was added for every 100,000 cells). The only additional modification made to the protocol was scaling down in volume of digest buffer to align with amount of lysis buffer (for example, 20 μL digest buffer for 20 μL lysis buffer). Samples were resuspended in 12 μL of LC-Load Buffer from the iST NHS kit and peptide concentration determined (Pierce Quantitative Colorimetric or Fluorescent Peptide Assay, ThermoFisher Scientific, Waltham, Massachusetts). Sample concentration was normalized to 100 ng/μL and 2 μL was loaded onto the instrument.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!