The largest database of trusted experimental protocols

Aviii hd 600 mhz

Manufactured by Bruker

The AVIII HD 600 MHz is a high-performance nuclear magnetic resonance (NMR) spectrometer designed and manufactured by Bruker. It operates at a magnetic field strength of 600 MHz, providing high-resolution data for a wide range of applications in chemical and biological research.

Automatically generated - may contain errors

2 protocols using aviii hd 600 mhz

1

NMR Spectroscopy of dsRBD-tRNA Interactions

Check if the same lab product or an alternative is used in the 5 most similar protocols
All NMR spectra of dsRBD and tRNA were measured at 303 K on a Bruker AVIII HD 600 MHz equipped with a cryoprobe in a buffer containing 25 mM sodium phosphate pH 6.5, 20 mM sodium chloride, 10 mM dithiothreitol (DTT) and 10% (v/v) D2O. The data were processed using TOPSPIN 3.5 (Bruker) and analyzed with Sparky (www.cgl.ucsf.edu/home/sparky/). The backbone resonances of dsRBD (residues 337–450) were assigned using 2D (1H,15N)-HSQC, 3D HNCA, 3D HNCACB, 3D CBCA(CO)NH, 3D HNCO and 3D NOESY-(1H,15N)-HSQC. For titration experiments, 0.35 mM of 15N-labeled dsRBD were mixed with increasing amount of unlabeled tRNALys3 up to 1 molar equivalent and 2D (1H,15N)-HSQC were recorded at each step. Similarly, the titration of 0.3 mM 15N-labeled tRNALys3 was performed with 2D (1H,15N)-TROSY experiments by adding increasing amount of unlabeled dsRBD up to 1 molar equivalent.
+ Open protocol
+ Expand
2

Analytical Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a JASCO P-1020 automatic digital polarimeter at room temperature. IR spectra were recorded on a Bruker Tensor 27 spectrometer using KBr pellets. UV spectra were recorded on a Shimadzu UV-2450 spectrophotometer (Shimadzu, Tokyo, Japan). High-resolution electrospray ionization mass spectrometry (HRESIMS) was obtained on an Agilent 6529B Q-TOF mass instrument using electrospray ionization. The 1D and 2D nuclear magnetic resonance (NMR) spectra were obtained on Bruker AVANCE III 500 MHz or Bruker AVIIIHD 600 MHz spectrometers in CDCl3 with TMS as an internal standard. Analytical HPLC was conducted on an Agilent 1260 infinity system equipped with a DAD-UV detector. Preparative HPLC was carried out using a Shimadzu LC-6A system (Shimadzu, Tokyo, Japan) equipped with a Shim-pack RP-C18 column (20 × 200 mm, i.d. 10 μm, Shimadzu, Tokyo, Japan) with a flow rate of 10.0 mL/min, detected by a binary channel UV detector. Silica gel (200–300 mesh, Qingdao Haiyang Chemical Co. Ltd., China), MCI (Mitsubishi, Japan), and RP-C18 silica (40–63 μm, FuJi, Japan) were used for column chromatography.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!