The largest database of trusted experimental protocols

Durapore polyvinylidene fluoride pvdf membrane

Manufactured by Merck Group
Sourced in Germany

Durapore polyvinylidene fluoride (PVDF) membrane is a type of lab equipment used for filtration and separation purposes. It is a hydrophilic polymer-based membrane that is chemically and thermally stable. The membrane is designed to provide efficient and reliable performance in various laboratory applications.

Automatically generated - may contain errors

2 protocols using durapore polyvinylidene fluoride pvdf membrane

1

Fractionation of Starch Polymers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Purified starch (30 mg for fractionation of rice starch and 20 mg for corn starch) was suspended in 1.6 mL of distilled water in a 15 mL centrifuge tube, and gelatinized with 400 µL of 5 M NaOH for 30 min at 37 °C. Distilled water (2 mL) and 2 mL of eluent (0.2 % NaCl / 0.05 M NaOH) were added, and samples were filtered through a 5 µm Durapore polyvinylidene fluoride (PVDF) membrane (Merck KGaA, Darmstadt, Germany). A 5 mL sample of filtrate was applied to a 4-column system comprising Toyopearl HW75S × 2, HW65S, and HW55S columns (2.2 cm diameter, 30 cm × 4; Tosoh Corp., Tokyo, Japan) pre-equilibrated with 0.2 % NaCl / 0.05 M NaOH, and carbohydrate was detected using a RI-8020 RI detector (Tosoh Corp.).16) Columns were incubated at 40 °C, and samples were eluted at a flow rate of 1 mL/min by using a DP-8020 pump (Tosoh Corp.).
+ Open protocol
+ Expand
2

Rice Flour Carbohydrate Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Rice flour samples (20 mg) were suspended in 1.6 mL of distilled water in a 15 mL centrifuge tube and gelatinized with 400 µL of 5 M NaOH for 30 min at 37 °C. Then, 2 mL of distilled water and 2 mL of eluent (0.2% NaCl/0.05 M NaOH) were added to each sample, followed by filtration through a 5 µm Durapore polyvinylidene fluoride (PVDF) membrane (Merck, Darmstadt, Germany). A 5 mL aliquot of the filtrate was used in a 4-column system (Toyopearl HW75S × 2-HW65S-HW55S; 2.2 cm diameter, 30 cm × 4; Tosoh Corp., Tokyo, Japan) that was pre-equilibrated with the eluent, and carbohydrates were detected using an RI detector (RI-8020; Tosoh Corp.). The columns were incubated at 40 °C, and the samples were eluted at a flow rate of 1 mL/min using a DP-8020 pump (Tosoh Corp.).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!