The largest database of trusted experimental protocols

2 protocols using kbr discs

1

Spectroscopic Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV spectra were recorded on Beckman DU 640 spectrophotometer (Beckman Coulter Inc., Brea, CA, USA). IR spectra were taken on Bruker tensor-27 spectrophotometer in KBr discs (Bruker Corporation, Billerica, MA, USA). Specific rotations were measured on JASCO P-1020 digital polarimeter (JASCO Corporation, Tokyo, Japan). ESIMS were obtained on Thermo Scientific LTQ Orbitrap XL mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) or Micromass Q-TOF ULTIMA GLOBAL GAA076 LC Mass spectrometer (Wasters Corporation, Milford, MA, USA). CD spectra were measured on JASCO J-715 spectropolarimeter (JASCO Corporation, Tokyo, Japan). NMR spectra were recorded on Agilent 500 MHz DD2 spectrometer using TMS as internal standard and chemical shifts were recorded as δ-values (Agilent Technologies Inc., Santa Clara, CA, USA). Semi-preparative HPLC was performed on an ODS column (HPLC (YMC-Pack ODS-A, 10 × 250 mm, 5 μm, 3 mL/min)) (YMC Co., Ltd., Kyoto, Japan). Medium-pressure preparation liquid chromatography (MPLC) was performed on a Bona-Agela CHEETAHTM HP100 (Beijing Agela Technologies Co., Ltd., Beijing, China). Column chromatography (CC) were performed with silica gel (200–300 mesh, Qingdao Marine Chemical Inc., Qingdao, China), and Sephadex LH-20 (Amersham Biosciences, San Francisco, CA, USA), respectively [27 (link)].
+ Open protocol
+ Expand
2

Synthesis and Characterization of Betulinic Acid Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial reagents were purchased from Sigma-Aldrich and Acros organics (Verona, Italy). Betulinic acid was prepared from commercially available betulin by a reported procedure [16 (link)]. All commercially available solvents and reagents used were of analytical grade and without further purification. Reactions were monitored by TLC on Sorbfil plates. Column chromatography was carried out on Acrus silica gel (0.060–0.200 mm). Optical rotations were measured on a Perkin–Elmer 341 polarimeter (Waltham, MA, USA). Melting points were recorded on Stuart SMP3. IR spectra were recorded on Bruker VERTEX 70 V using KBr discs over the range of 400–4000 cm−1 (Billerica, MA, USA). 1H and 13C NMR spectra were obtained using a Bruker Ascend 500 spectrometer in CDCl3 operating at 500 MHz for 1H and 125 MHz for 13C and a Bruker AVANCE 400 spectrometer in CDCl3 operating at 400 MHz for 1H and 100 MHz for 13C. Mass spectra of MALDI TOF/TOF positive ions (matrix of sinapic acid) are recorded on a mass spectrometer Bruker AutoflexTM III Smartbeam. Elemental analyses were measured on 1106 Carlo Erba apparatus (Val de Reuil, France). Figures S1–S99 show the 1H and 13C NMR spectra of the synthesized compounds.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!