The largest database of trusted experimental protocols

Human pool a v2

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Human Pool A v2.1 is a laboratory equipment designed for the collection and processing of human biological samples. It provides a controlled environment for the handling and storage of these samples. The core function of this product is to facilitate the collection, preparation, and preservation of human biological materials for further analysis and research purposes.

Automatically generated - may contain errors

2 protocols using human pool a v2

1

Urinary Exosome miRNA Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
From the 12 μl urinary exosome isolation, the authors assessed miRNA abundance for 754 miRNAs using TaqMan® OpenArray® qPCR technology (Thermo Fisher Scientific). Briefly, reverse transcription and preamplification of all RNA samples were performed using Megaplex reverse transcription primers (Thermo Fisher Scientific), Human Pool A v2.1 (4399966; Thermo Fisher Scientific) and Human Pool B v3.0 (4444281; Thermo Fisher Scientific) and Megaplex preamp primers (Thermo Fisher Scientific), Human Pool A v2.1 (4399233; Thermo Fisher Scientific) and Human Pool B v3.0 (4444748; Thermo Fisher Scientific) following the manufacturer's protocol. The qPCR was performed using QuantStudio 12 K flex (Thermo Fisher Scientific) and relative quantification cycle (Cq) values were calculated using QuantStudio software (Thermo Fisher Scientific).
+ Open protocol
+ Expand
2

Profiling Cellular microRNA Levels

Check if the same lab product or an alternative is used in the 5 most similar protocols
MicroRNA TaqMan® Arrays (Thermofisher Scientific, Waltham, MA, USA) were performed as previously described [106 (link)]. Briefly, 300 ng of total RNA isolated from each of the three biological replicates of U87MG, transfected for 24 h with the vector pcDNA3.1_circSMARCA5 or with NC, were reverse-transcribed into specific cDNAs of 748 microRNAs using the TaqMan™ MicroRNA Reverse Transcription Kit (ThermoFisher Scientific, Waltham, MA, USA) and the Megaplex™ RT Primers Human Pool A v 2.1 and Pool B v 3.0 (ThermoFisher Scientific, Waltham, MA, USA). The products of Megaplex™ reactions were then pre-amplified using the following kits: Megaplex™ PreAmp Primers, Human Pool A v. 2.1, and Human Pool B v. 3.0 (ThermoFisher Scientific, Waltham, MA, USA), according to the manufacturer’s instructions. The Megaplex™ PreAmp product of each sample was then loaded into an independent TaqMan® Array MicroRNA Card A (in the case of samples reverse-transcribed and pre-amplified with pool A primers) or B (with samples reverse-transcribed and pre-amplified with pool B primers) (ThermoFisher Scientific, Waltham, MA, USA). PCR was performed using a QuantStudio™ 5 Real-Time PCR System (ThermoFisher Scientific, Waltham, MA, USA) (Figure S12).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!