The largest database of trusted experimental protocols

Serum cystatin c

Manufactured by R&D Systems
Sourced in United States

Serum cystatin C is a lab equipment product that measures the concentration of cystatin C, a small protein, in the blood. Cystatin C is a marker of kidney function and can be used to assess the glomerular filtration rate, which is the rate at which the kidneys filter waste from the blood.

Automatically generated - may contain errors

3 protocols using serum cystatin c

1

Comprehensive Blood and Urine Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was collected from the inferior vena cava at euthanasia. BUN was measured on the Beckman Coulter AU 680 analyzer. Blood counts were performed on the IDEXX Procyte DX analyzer. Both procedures were performed with the assistance of the Weill Cornell Medicine Laboratory of Comparative Pathology. Serum iron levels were measured using SFBC kits (Biolabo) following manufacturer’s instructions. We used ELISA to measure serum cystatin C (R&D Systems, Bio-Techne), serum soluble TfR (MyBioSource), and urine albumin (Abcam) following manufacturers’ instructions.
+ Open protocol
+ Expand
2

Biomarkers of Cardiac Surgery Injury

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum and urine samples were obtained preoperatively, hour 6 after CPB, and daily on PODs 1 to 4. Serum samples were centrifuged at 1227g for 15 minutes at 4 °C. Urine samples were centrifuged at 626g for 30 minutes at 4 °C. Serum and urine aliquots were stored at −80 °C until thawed for batch analysis. Urine creatinine concentrations were measured by capillary electrophoresis. Enzyme-linked immunosorbent assays were used to measure serum cystatin C (R&D Systems, Minneapolis, MN), urine KIM-1 (R&D Systems), and urine NGAL (BioPorto Diagnostics, Hellerup, Denmark). The lower limit of detection for urine KIM-1 was 0.156 ng/ml. Of the total of 598 urine samples, only 6 values were below this limit, and these values were analyzed as being 0.156 ng/ml. Measurements of cystatin C and NGAL were not below the lower limits of detection for their respective assays. Urine NGAL and KIM-1 values were normalized by urine Cr level.
+ Open protocol
+ Expand
3

Serum Biomarkers of Oxidative Stress

Check if the same lab product or an alternative is used in the 5 most similar protocols
Enzyme-linked immunosorbent assay (ELISA) kits were used to estimate serum cystatin C (R&D Systems, USA), neutrophil gelatinase-associated lipocalin (NGAL), NADPH oxidase, nuclear factor erythroid 2-related factor 2 (Nrf2) (Cusabio, China), hemeoxygenase-1(HO-1) (Enzo Life Sciences, Egypt), heat shock protein 90 (HSP 90) (Bioassay™, USA), nuclear factor kappa-B (NF-κB) (Eiaab, China) and tumor necrosis factor-α (TNF-α) (Raybio, USA). Reduced glutathione (GSH) and blood urea nitrogen (BUN) were estimated using glutathione reduced and blood urea nitrogen colorimetric kits, respectively (Biodiagnostic, Egypt). Total antioxidant capacity (TAC) was assessed by antioxidant assay kit (Zenbio, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!