The largest database of trusted experimental protocols

Gx 271 liquid handler

Manufactured by Gilson
Sourced in United States

The GX-271 Liquid Handler is a laboratory automation instrument designed for precise liquid handling. It can accurately and reproducibly dispense and aspirate a variety of liquids across a range of volumes. The GX-271 is capable of automating liquid handling tasks to improve efficiency and consistency in laboratory workflows.

Automatically generated - may contain errors

3 protocols using gx 271 liquid handler

1

Soil-Atmosphere N2O Flux Measurements

Check if the same lab product or an alternative is used in the 5 most similar protocols
N2O fluxes between the soil and the atmosphere were measured in the study areas (Table 1) during the summer of 2013 [13 ] by using the static chamber method [62 ]. N2O flux measurements were done once a month in June, July and August on polyvinyl chloride collars (6 collars per plot; diameter 0.22 m and height 0.05 m). The gas samples taken from chambers (height = 0.24 m and diameter = 0.2 m) were analyzed by an Agilent Gas Chromatograph model 7890A (GC, Agilent Technologies, USA) equipped with an autosampler (Gilson GX-271 Liquid Handler) by using a Flame Ionization Detector. Samples were analyzed using six-point standard curve [62 ]. The N2O fluxes were calculated by using linear regression fitted to time and concentration change inside the chamber headspace. The annual N2O fluxes for different aged stands were calculated by converting the measured amount of N2O (mg m-2 s-1) per hectare and multiplying them by the average length of the growing season (120 days) of the study area. The annual N2O fluxes for non-measured periods were linearly interpolated from sequential measured values.
+ Open protocol
+ Expand
2

HPLC-DAD Analysis of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-DAD for analysis was performed on Gilson GX-271 Liquid Handler with system 322 H2 Pump connected to a 171 Gilson Diode Array Detector and fraction collector. A XBridge BEH C18 XP Column (130 Å, 2.5 μm, 4.6 mm × 100 mm) with XBridge BEH C18 XP VanGuard Cartridge (130 Å, 2.5 μm, 3.9 mm × 5 mm) was used for analytical run with a flow rate of 0.8 ml/min. HPLC-grade water with 0.5% formic acid (solvent A) and HPLC-grade acetonitrile with 0.5% formic acid (solvent B) were used with the following gradients: 0 min, 20% Solvent B; 2 min, 20% Solvent B; 15 min, 95% Solvent B; 18 min, 95% Solvent B; 20 min, 20% Solvent B. Data acquisition and procession for the HPLC-DAD were controlled by TRILUTION LC V3.0.
+ Open protocol
+ Expand
3

HPLC-DAD Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-DAD for analysis was performed on Gilson GX-271 Liquid Handler with system 322 H2 Pump connected to a 171 Gilson Diode Array Detector and fraction collector. A XBridge BEH C18 XP Column (130 Å, 2.5 μm, 4.6mm × 100mm) with XBridge BEH C18 XP VanGuard Cartridge (130 Å, 2.5 μm, 3.9mm × 5mm) was used for analytical run with a flow rate of 0.8 ml/min. HPLC-grade water with 0.5% formic acid (solvent A) and HPLC-grade acetonitrile with 0.5% formic acid (solvent B) were used with the following gradients: 0min, 20% Solvent B; 2min, 20% Solvent B; 15 min, 95% Solvent B; 18 min, 95% Solvent B; 20 min, 20% Solvent B. Data acquisition and procession for the HPLC-DAD were controlled by TRILUTION LC V3.0.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.