The Omron HEM-7320-LA is a blood pressure monitor designed for professional use in medical facilities. It measures the user's blood pressure and heart rate. The device features easy-to-read digital display and automatic inflation and deflation of the cuff. It is intended for use by healthcare professionals as part of routine patient assessments.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using hem 7320 la

1

Automated Upper Arm Blood Pressure Monitor

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Omron HEM-7320-LA (Omron Healthcare Co. Ltd, Kyoto, Japan) is an automatic oscillometric device for measuring BP at the upper arm and has a pressure range of 0–299 mmHg and a heart rate range of 40–180 beats/min. The systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate are displayed on a liquid crystal digital display. The inflation function uses a fuzzy-logic system controlled by an electric pump and deflation is by means of an automatic pressure release valve. The dimensions of this device are (width×height×depth) 124×90×161 mm. The cuff Intelli Wrap HEM-FL32 (Omron Healthcare Co. Ltd) included in the device provides a wide range of arm circumferences of 22–42 cm (9–17 inch), avoiding undercuffing, which has been proven to be a key source of error BP measurement 8 (link). The cuff is also preformed, which makes it easier to place it on in the arm by a single hand also by the patient himself/herself, making BP measurement even more simple, which can avoid incorrect BP. The integrated movement sensor detects body movements, the cuff displays whether it fits correctly, and the arrhythmia detection warns if the heartbeats are irregular.
+ Open protocol
+ Expand
2

Anthropometric and Cardiovascular Measurements

Check if the same lab product or an alternative is used in the 5 most similar protocols
Clinical history, physical examination, and anthropometric measurements were obtained for all subjects. Height and weight were measured using a SECA stadiometer and a SECA scale respectively, and body mass index (BMI) was calculated as kilogram per square meter (kg/m2). Waist circumference (WC) was measured using Lufkin® metallic tape, (Crescent Lufkin, Saginaw, Michigan, USA) and blood pressure was measured with an Omron HEM-7320-LA electronic monitor (Omron Healthcare Co. Ltd., Kyoto, Japan), twice in the right arm after a 5 min rest in a sitting position, and the average of the 2 measurements was recorded. All evaluations were performed by trained personnel.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!