Oasis prime hlb spe cartridges

Manufactured by Waters Corporation
Sourced in United States

The OASIS PRIME HLB SPE cartridges are solid-phase extraction (SPE) products manufactured by Waters Corporation. They are designed for sample preparation and analyte extraction from various matrices. The cartridges utilize a hydrophilic-lipophilic balanced (HLB) sorbent to facilitate the retention and elution of a wide range of analytes.

Automatically generated - may contain errors

4 protocols using oasis prime hlb spe cartridges

1

Pharmacokinetic Study of CTE, NGTS, and CNP

Check if the same lab product or an alternative is used in the 5 most similar protocols
CTE, NGTS, and CNP powders were dissolved using saline, and were orally dosed at 50 mg·kg−1, 60 mg·kg−1, and 50 mg·kg−1 CTE + 60 mg·kg−1 NGTS, respectively, whereas saline was administered to the vehicle group. Six rats were used in each group, and all rats fasted overnight but had free access to water prior to treatment. A terminal sampling design was used to collect blood samples at 0 (pre-dose), 0.08, 0.16, 0.25, 0.5, 1, 2, 3, 4, 6, 8, 12, 24, 48, 72, and 96 h. At each time, 0.5 mL of blood was collected in the heparin sodium tubes. Plasma was separated by centrifugation at 4000 rpm for 10 min and stored below −80 °C until bioanalysis. Oasis PRiME HLB SPE cartridges (1 cc/30 mg, Waters, Milford, MA, USA) were used to process the plasma samples (Supplementary Materials).
+ Open protocol
+ Expand
2

Synthesis and Purification of Phenanthrenequinones

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,2-Phenanthrenequinone (1,2-PheQ) and 3,4-phenanthrenequinone (3,4-PheQ) were prepared as previously described (Figure 3) (Magdziak et al., 2002 (link)).) [13C4]1,2-PheQ was similarly prepared from [13C4]1-hydroxyphenanthrene ([13C4]1-OHPhe), Cambridge Isotope Laboratories, Inc. (Tewksbury, MA, USA). 1-Hydroxyphenanthrene (1-OHPhe) and 4-hydroxyphenanthrene (4-OHPhe) were obtained from Toronto Research Chemicals (North York, ON, Canada). 9,10-Phenanthrenequinone (9,10-PheQ), benzaldehyde, formic acid, ammonium acetate and sodium acetate were purchased from Millipore Sigma (St. Louis, MO, USA). 8-iso-PGF and [D4]8-iso-PGF were procured from Cayman Chemical (Ann Arbor, MI, USA). β-Glucuronidase and arylsulfatase (from Helix pomatia) were obtained from Roche Diagnostics Corp. (Indianapolis, IN, USA). Oasis® PRiME HLB SPE cartridges (200 mg/6 mL/# 186008057) were from Waters (Milford, MA, USA). A Bond Elut C18 96 square-well plate (100 mg/2 mL/# A396011C) was purchased from Agilent (Santa Clara, CA, USA). All solvents used in this study including hexane, isopropanol, acetonitrile, ethyl acetate and methanol were HPLC grade and obtained from Fisher Scientific (Fair Lawn, NJ, USA). Ultrapure H2O from a Millipore Milli-Q Advantage A10 Water Purification System was used throughout the study.
+ Open protocol
+ Expand
3

Chromatographic Separation and Immunoassay of Mycotoxins in Feed

Check if the same lab product or an alternative is used in the 5 most similar protocols
The reagents used in the chromatographic separation of mycotoxins and their extraction from feed samples were: acetonitrile (ACN) and methanol (MeOH), both of gradient grade and purchased from Honeywell Riedel-de Haën (Muskegon, MI, USA); chloroform and water, also liquid chromatography (LC) gradient grade, provided by Fisher Scientific (Bishop Meadow, UK); and pro-analysis grade orthophosphoric acid obtained from Panreac (Barcelona, Spain). In addition, OASIS PRIME HLB SPE cartridges were obtained from Waters (Milford, MA, USA). In the case of DON and STER analysis, commercial enzyme-linked immunosorbent assay (ELISA) kits suitable for mycotoxin quantification in feed were used. For DON analysis, the RIDASCREEN® FAST DON SC kit (Art. No. R5905 R-Biopharm AG, Darmstadt, Germany) was employed; while for STER quantification, the Creative-diagnostic Sterigmatocystin DEIANJ08 ELISA kit was selected (NY, USA). In both cases, all the reagents needed were included in the kits.
+ Open protocol
+ Expand
4

LC-gradient Solvent Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-gradient grade acetonitrile (ACN) and methanol (MeOH) were purchased from Honeywell Riedel-de Haën (Muskegon, MI, USA). LC-gradient grade chloroform and water were obtained from Fisher Scientific (Bishop Meadow, UK). Pro-analysis grade orthophosphoric acid was obtained from Panreac (Barcelona, Spain). OASIS PRIME HLB SPE cartridges were obtained from Waters (Milford, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!