The largest database of trusted experimental protocols

Model 240 c

Manufactured by PerkinElmer
Sourced in United States

The Model 240 C is a versatile piece of laboratory equipment designed for conducting a range of analytical tests. It features a compact and durable construction, making it suitable for use in various laboratory settings. The core function of this model is to provide accurate and reliable data for researchers and scientists.

Automatically generated - may contain errors

4 protocols using model 240 c

1

Spectroscopic Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals, reagents, and solvents were bought from Sigma company and were used without further purification. The 1H NMR spectra were recorded on a Bruker Unity 300 or 400 MHz spectrometer. The 13C NMR spectra were also recorded at 75 or 100 MHz. The chemical shifts are given in ppm and were referenced with the residual solvent resonances relative to tetramethylsilane (TMS). The mass spectra were obtained on a Finnigan MAT 312 mass spectrometer, connected to a PDO 11/34 (DEC) computer system by electron impact. The elemental analyses were determined using a Perkin Elmer Model 240-C instrument (PerkinElmer, Hopkinton, MA, USA). The melting points were measured on a SMP1 Stuart apparatus and are uncorrected. Flash chromatography was conducted using MERCK silica gel (mesh size 230–400 ASTM). Thin-layer chromatography (TLC) was performed on Macherey-Nagel poly gram Sil G/UV254 silica gel plates, with visualization under UV (254 nm).
+ Open protocol
+ Expand
2

Characterization of Synthesized Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The IR spectra of the synthesized compounds were analyzed using Perkin-Elmer Spectrum FT-IR spectrometer (RX-1) operating in the region 4000 to 400 cm−1 in KBr. 1H NMR spectra were recorded at room temperature on a FT-NMR (Bruker Advance-II 400 MHz) spectrometer using DMSO‑d6 as solvents and chemical shifts are quoted in ppm downfield of internal standard tetramethylsilane (TMS). Elemental microanalyses (C, H and N) were conducted by using Perkin–Elmer (Model 240C) analyzer. The purity of the prepared compounds was confirmed by thin layer chromatography (TLC) on silica gel plates and the plates were visualized with UV-light and iodine as and when required.
+ Open protocol
+ Expand
3

Characterization of Magnolol and Honokiol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points are uncorrected. All 1H NMR and 13C NMR spectra were recorded on spectrometer Varian Mercury Plus operating at 399.93 MHz and 100.57 MHz, respectively. Chemical shifts are given in ppm (δ) and coupling constants in Hertz; multiplicities are indicated by s (singlet), d (doublet), t (triplet), ddt (doublet doublet triplet), m (multiplet) or series of m (series of multiplet). CDCl3, acetone-d6, were used as solvents as indicated below. Shifts are given in ppm relative to the remaining protons of the deuterated solvents used as internal standard (1H, 13C). Elemental analyses were performed using an elemental analyser Perkin-Elmer model 240 C. Ethanol (EtOH) grade 96% was used, dry acetone was freshly distilled from CaCl2 under N2. All reagents were of commercial quality and used as purchased from various producers (Sigma-Aldrich, Merck). Magnolol 1 and honokiol 2 were purchased from Chemos GmbH, Germany. Flash chromatography was carried out with silica gel 60 (230–400 mesh, Kiesgel, EM Reagents) eluting with appropriate solution in the stated v:v proportions. Analytical thin-layer chromatography (TLC) was performed with 0.25 mm thick silica gel plates (Polygram® Sil G/UV254, Macherey-Nagel). The purity of all new compounds was judged to be >98% by 1H-NMR spectral determination. Solvents were used without additional purification or drying, unless otherwise noted.
+ Open protocol
+ Expand
4

Synthesis and Characterization of Biphenyls

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points are uncorrected. All 1H NMR and 13C NMR spectra were recorded in CDCl3 solution at 399.93 MHz and 100.57 MHz, respectively. Chemical shifts are given in ppm (δ; multiplicities are indicated by s (singlet), d (doublet), t (triplet), ddt (doublet doublet triplet), m (multiplet) or bs (broad singlet). Elemental analyses were performed using an elemental analyser Perkin-Elmer model 240 C Optical rotations were measured with a Perkin-Elmer 343 spectropolarimeter. Toluene was freshly distilled from sodium benzophenone ketyl and acetone was dried over CaCl2 and distilled before use. Ethanol (EtOH) grade 96% was used. All reagents were of commercial quality and used as purchased. Flash chromatography was carried out with silica gel 60 (230-400 mesh, Kiesgel, EM Reagents) eluting with appropriate solution in the stated v:v proportions. The purity of all new compounds was judged to be >98% by 1H-NMR and 13C-NMR spectral determination. Biphenyls 15 and 16 were prepared as previously described [17 , 18 ].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!