The largest database of trusted experimental protocols

Sequant zic philic 5 μm polymeric 150 2.1 mm peek coated hplc column

Manufactured by Merck Group
Sourced in United States

The SeQuant® ZIC®-pHILIC 5 μm polymeric 150 × 2.1 mm PEEK-coated HPLC column is a high-performance liquid chromatography (HPLC) column designed for the separation and analysis of polar and hydrophilic compounds. The column features a zwitterionic (ZIC) stationary phase and a particle size of 5 μm. The column is coated with PEEK (polyether ether ketone) for chemical and physical durability.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using sequant zic philic 5 μm polymeric 150 2.1 mm peek coated hplc column

1

HILIC-based HPLC-MS Metabolite Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
The mass spectrometer was coupled to a Shimadzu HPLC (Nexera X2 LC-30AD). Chromatography was performed under HILIC conditions using a SeQuant® ZIC®-pHILIC 5 μm polymeric 150 × 2.1 mm PEEK-coated HPLC column from MilliporeSigma, USA. The column temperature, sample injection volume, and flow rate were set to 45 °C, 5 μL, and 0.15 mL/min, respectively. The HPLC conditions were as follows: Solvent A: 20 mM ammonium carbonate including 0.1% ammonium hydroxide, and Solvent B: acetonitrile. The gradient conditions were as follows: 0 min: 80% B, 20 min: 20% B, 21 min: 80% B, and 34 min: 80% B. The total run time was 34 min.
+ Open protocol
+ Expand
2

Quantitative Metabolite Profiling by HILIC-HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chromatography was performed under HILIC conditions using a SeQuant® ZIC®-pHILIC 5 μm polymeric 150 × 2.1 mm PEEK coated HPLC column, MilliporeSigma, USA. The column temperature, sample injection volume, the flow rate was set to 45 °C, 5 μL, and 0.15 mL/min respectively. The HPLC conditions were as follows: Solvent A: 20 mM ammonium carbonate including 0.1% Ammonium hydroxide. Solvent B: Acetonitrile. Gradient condition was 0 min: 80% B, 20 min: 20% B, 20.5 min 80% B, 34 min: 80% B. Total run time: 34 mins. Data was processed by SCIEX MultiQuant 3.0.3 software with relative quantification based on the peak area of each metabolite.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!