2 protocols using 2 kd mwco slide a lyzer dialysis cassettes

1

Screening Organic Acids and Peroxidase Activity

Check if the same lab product or an alternative is used in the 5 most similar protocols
The chemicals, their sources, purity, and CAS #s were: adipic acid, TCI, ≥ 99%, 124-04-9; ammonium nitrate, Fisher, ACS grade, 6484-52-2; citric acid monohydrate, Fisher, ACS grade, 5949-29-1; DL-3-hydroxybutyric acid sodium salt, Chem Impex Int’l Inc., 100.30%, 150-83-4 & 306-31-0; DL-malic acid, Alfa Aesar, 98%, 6915-15-7; glutaric acid, Acros organics, 99%, 110-94-1; hydrogen peroxide 3% W/W, BDH chemicals, 7722-84-1; horseradish peroxide type II, Sigma, 150-250 U/mg, 9003-99-0; lactic acid, TCI, ≥ 85%, 50-21-5; pimelic acid, Alfa Aesar, 98+%, 111-16-0; sodium acetate, VWR, ACS grade, 127-09-3; sodium azide, Sigma, 99.8%, 26628-22-8; sodium nitrate, BDH chemicals, ACS grade, 7631-99-4; succinic acid, TCI America, ≥ 99%,110-15-6; and tricarballylic acid, Alfa Aesar, 98%, 99-14-9. For electron microscopy, hexagonal copper square grids with 200 mesh carbon support film from Electron Microscopy Sciences were used. Pierce Biotechnology’s 2 kD MWCO Slide-A-Lyzer™ dialysis cassettes were used.
+ Open protocol
+ Expand
2

Analytical Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The chemicals, their sources, purity, and CAS numbers were adipic acid,
TCI, ≥ 99%, 124-04-9; ammonium nitrate, Fisher, ACS grade, 6484-52-2;
citric acid monohydrate, Fisher, ACS grade, 5949-29-1; DL-3-hydroxybutyric acid
sodium salt, Chem Impex Int’l Inc., 100.30%, 150-83-4 & 306-31-0;
DL-malic acid, Alfa Aesar, 98%, 6915-15-7; glutaric acid, Acros organics,
99%,110-94-1; hydrogen peroxide 3% W/W, BDH chemicals, 7722-84-1; horseradish
peroxide type II, Sigma, 150-250 U/mg, 9003-99-0; lactic acid, TCI, ≥
85%, 50-21-5; pimelic acid, Alfa Aesar, 98+%, 111-16-0; sodium acetate, VWR, ACS
grade, 127-09-3; sodium azide, Sigma, 99.8%, 26628-22-8; sodium nitrate, BDH
chemicals, ACS grade, 7631-99-4; succinic acid, TCI America, ≥
99%,110-15-6; and tricarballylic acid, Alfa Aesar, 98%, 99-14-9. The electron
microscopy grids were 200 mesh carbon support film on hexagonal copper square
grids from Electron Microscopy Sciences. Pierce Biotechnology’s 2 kD MWCO
Slide-A-Lyzer™ dialysis cassettes were used. Trace metal grade
concentrated nitric acid was from Fisher. ICP/DCP Ce ion standard solution was
from Aldrich.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!