The largest database of trusted experimental protocols

Cis trans 18 2n 6

Manufactured by Merck Group

Cis/trans 18:2n-6 is a laboratory equipment product used for the analysis and identification of fatty acid isomers. It serves as a standard reference material for the characterization of cis and trans isomers of linoleic acid (18:2n-6).

Automatically generated - may contain errors

2 protocols using cis trans 18 2n 6

1

Fatty Acid Profiling and Desaturase Activity

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total lipids were extracted from the plasma samples and converted to their methyl ester equivalents as described previously (12 (link), 22 (link)), and analyzed using an Agilent 7820A GC using flame ionization detection on a SP-2560 polar fused silica capillary column (100 m × 0.25 mm × 0.2 μm; Supelco Inc., PA, USA) with nitrogen as the carrier gas (12 (link)). The FA peaks were identified by comparing retention times with those of a standard mixture of GLC-68A, GLC-481B, GLC-532, GLC-744 (Nu-Chek Prep), 37 FAME, trans 16:1n-7, trans 18:1n-7, trans 18:1n-9, and cis/trans 18:2n-6 (all obtained from Supelco Inc., or Sigma). 13:0 free fatty acid (10 μg) was added as an internal standard. FA composition was expressed as the weight of a percentage of the total weight of carbon-12 to carbon-24 FAs (wt%). The estimated desaturase activity was calculated using the ratio of FA in plasma (11 (link), 17 (link), 23 (link)); SCD1(16) activity = (16:1n-7/16:0), SCD1(18) activity = (18:1n-9/18:0), D5D activity = (20:4n-6/20:3n-6), and D6D activity = (20:3n-6/18:2n-6).
+ Open protocol
+ Expand
2

Plasma Fatty Acid Methyl Ester Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma FA methyl esters were prepared as described previously (Moser et al., 1999) [24 (link)]. Briefly, 200 μl plasma and 10 μg C13:0 as an internal standard were mixed with 1 ml methanol/methylene chloride 3:1 (v/v). Subsequently, 200 μl of acetyl chloride, were added and the samples were placed in a 75°C water bath for 1 h. After cooling down, 4 ml of 7% potassium carbonate and 2 ml hexane were added, and samples were mixed and centrifuged for 10 min at 3000 rpm at room temperature. The plasma sample in hexane layer was dried using nitrogen gas and analyzed with Agilent 7820A GC using flame ionization detection on a SP-2560 polar fused silica capillary column (100 m x 0.25 mm x 0.2 μm, Supelco Inc.) with nitrogen as carrier gas. The oven temperature program was initially set to 60°C for 1 min, then increased by 25°C per minute to 160°C, then increased by 2°C per minute to 240°C for 10 min, and finally increased by 5°C per minute to 245°C for 5 min. The FA peaks were identified by comparing retention times from our samples with retention times of a standard mixture of GLC-68A, GLC-481, GLC-532, GLC-744 (Nu-Chek Prep), 37 FAME, cis/trans 18:2n-6 and cis/trans 18:3n-3, (all from SUPELCO). The FA composition was expressed as the weight of a percentage of the total weight of carbon 12 to carbon 24 FAs (wt%). http://dx.doi.org/10.17504/protocols.io.h6hb9b6
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!