NMR Analysis of Modified Fructans

Check if the same lab product or an alternative is used in the 5 most similar protocols
H1 NMR analysis for NAF, HPAF, and HDPAF unmodified and their modified derivatives was performed on a nuclear magnetic resonance spectrometer (Agilent Technologies, model DD2 500 MHz, CA, USA). Fifteen mg of sample and 500 μL of D2O were used as a solvent in the unmodified fructans. While in the lauroylated, acetylated, and succinylated samples, CD3OD, CD3COCD3 and D2O were used as solvents, respectively. Spectral analysis and visualization were performed with MestReNova (Mestrelab Research. Chemistry Software Solutions. Version. 12.0.0-20080.2.2.2.3). The degree of substitution (DS) of the modified fructans was calculated as the ratio between the area under the peak at 0.8–1.2 ppm divided by three (assigned to the methylene protons) and the area under the signal of the glucosidic proton of glucose [5 (link)].
+ Open protocol
+ Expand
2

Synthesis and Characterization of Eu(III) Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
The compounds EuCl3·6H2O (99.9%, Aldrich) and 4,4,5,5,6,6,6-heptafluoro-1-(2-thienyl)-1,3-hexanedione (hth) (Apollo Scientific), and the co-ligands dpso (97%, Aldrich), dpsoCH3 (97%, Aldrich), dpsoCl (97%, Aldrich), and tppo (>98%, Fluka) were used without further purification. The NMR spectra of the complexes, in CDCl3 (99.8%, Cambridge Isotope Labs) at 25 °C, were recorded on a Varian Mercury 400 MHz and on an Agilent DD2 500 MHz equipped with the OneNMR probe NMR spectrometers. The infrared spectra were recorded using a VERTEX 70v Bruker FT-IR spectrometer, examining powder samples in anhydrous KBr via diffuse reflection spectroscopy. Elemental analyses were carried out using a Thermo Scientific™ FLASH 2000 CHNS/O Analyzer at the Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara.
+ Open protocol
+ Expand
3

Synthetic Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercially available chemicals of the appropriate purity were purchased from Merck (Kenilworth, NJ, U.S.A.) or Sigma ((St. Louis, MO, U.S.A.). The IR spectra were recorded on a Perkin Elmer Spectrum BX FT-IR spectrometer (Waltham, MA, U.S.A.). The 1H NMR and 13C NMR spectra were recorded using a BRUKER Avance III-300 MHz (Billerica, MA, U.S.A.) or an AGILENT DD2-500 MHz ((Santa Clara, CA, U.S.A.) spectrometer. Chemical shifts were reported in δ (ppm) and signals were given as follows: s, singlet; d, doublet; t, triplet; m, multiplet. Melting points (mp) were determined with a MEL-TEMPII apparatus, Laboratory Devices, Sigma-Aldrich (Milwaukee WI, U.S.A) and were uncorrected. The microanalyses were performed on a Perkin-Elmer 2400 CHN elemental analyser (Waltham, MA, U.S.A.). Thin-layer chromatography (TLC silica gel 60 F254 aluminium sheets, Merck (Kenilworth, NJ, U.S.A.) was used to follow the reactions and the spots were visualised under UV light.
+ Open protocol
+ Expand
4

Synthesis and Characterization of Xanthiniums

Check if the same lab product or an alternative is used in the 5 most similar protocols
All materials are commercially available and were used as received without further purification. Thin-layer chromatography (TLC) was performed on commercial silica gel plates (250 μm, Silicycle F254) and compounds were visualized using UV light or KMnO4. The compounds were purified on silica gel column (200–300 mesh) unless stated otherwise. IR spectra were measured on a Bomem Michelson 100 Series FTIR spectrometer. 1H, 13C, and 19F NMR spectra were recorded on a Bruker AC 300 MHz, Varian Inova 400 MHz or Agilent Technologies DD2 500 MHz spectrometers. Chemical shifts are given in ppm and residual solvent peaks were used as reference. The coupling constants were reported in hertz. High-resolution mass spectra (HRMS) were recorded on a LC/MS-TOF Agilent 6210 mass spectrometer (electrospray ionization). Xanthiniums were synthesized according to published procedures.19,30a,38 (link)
+ Open protocol
+ Expand
5

Analytical Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercially available chemicals of the appropriate purity were purchased from Sigma (St. Louis, MO, USA) or Merck (Kenilworth, NJ, USA). The 1H-NMR and 13C-NMR spectra were recorded using an AGILENT DD2-500 MHz (Santa Clara, CA, USA) spectrometer. Chemical shifts were reported in δ (ppm) and signals were given as follows: s, singlet; d, doublet; t, triplet; m, multiplet. Melting points (mp) were determined with a MEL-TEMPII apparatus, Laboratory Devices, Sigma-Aldrich (Milwaukee WI, USA) and were uncorrected. The microanalyses were performed on a Perkin-Elmer 2400 CHN elemental analyzer (Waltham, MA, USA). Thin-layer chromatography (TLC silica gel 60 F254 aluminum sheets, Merck (Kenilworth, NJ, USA) was used to follow the reactions and the spots were visualized under UV light.
+ Open protocol
+ Expand
6

Spectroscopic Characterization of NSAIDs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available chemicals of the appropriate purity were purchased from Merck (Kenilworth, NJ, USA) or Sigma (St. Louis, MO, USA). The IR spectra were recorded on a Perkin Elmer Spectrum BX FT-IR spectrometer (Waltham, MA, USA). The 1H NMR and 13C NMR spectra were recorded using an AGILENT DD2-500 MHz (Santa Clara, CA, USA) spectrometer. Chemical shifts were reported in δ (ppm) and signals are as follows: s, singlet; d, doublet; t, triplet; m, multiplet. Melting points (m.p.) were determined with a MEL-TEMPII apparatus, Laboratory Devices, Sigma-Aldrich (Milwaukee, WI, USA) and were uncorrected. The microanalyses were performed on a Perkin-Elmer 2400 CHN elemental analyzer (Waltham, MA, USA). Thin-layer chromatography (TLC silica gel 60 F254 aluminum sheets, Merck (Kenilworth, NJ, USA) was used to follow the reactions and the spots were visualized under UV light. Ibuprofen and ketoprofen were racemates, naproxen was the S-enantiomer.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!