The largest database of trusted experimental protocols

I bet762

Manufactured by MedChemExpress
Sourced in United States

I-BET762 is a potent and selective bromodomain (BRD) inhibitor, targeting the BRD4 protein. It acts by binding to the bromodomain of BRD4, thereby disrupting its interaction with acetylated histones and regulating gene transcription.

Automatically generated - may contain errors

2 protocols using i bet762

1

Pancreatic Cancer Cell Line Cultivation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Panc1 (CRL-1469), MiaPaCa2 (CRL-1420), and Su86 (CRL-1837; SU.86.86) pancreatic cancer cell lines were purchased from the American Type Culture Collection (Manassas, VA, USA). All cells were cultured under the recommended conditions. All cell lines used were tested for mycoplasma using MycoAlertTM PLUS Mycoplasma Detection Kit (Lonza, Walkersville, MD, USA), and the results were negative. Gemcitabine hydrochloride (G-4177, LC Laboratories, Woburn, MA, USA) was dissolved in sterile phosphate-buffered saline or 0.9% saline solution for in vitro and in vivo experiments, respectively. JQ1 (HY-13030, MedChem Express, Monmouth Junction, NJ, USA) and I-BET762 (MedChem Express) were dissolved in DMSO. DMSO concentration was <0.1% in vitro.
+ Open protocol
+ Expand
2

Cholangiocarcinoma Cell Lines and Drug Treatments

Check if the same lab product or an alternative is used in the 5 most similar protocols
KKU-055 (JCRB1551) and KKU-100 (JCRB1568) cholangiocarcinoma cell lines were purchased from the Japanese Cancer Research Resources Bank (JCRB) (National Institute of Biomedical Innovation, Japan). Cells were cultured in DMEM (Fisher Scientific, Waltham, MA, USA) supplemented with 10% fetal bovine serum (Atlanta Biologicals, Flowery Branch, GA, USA) and 2 mM L-glutamine (Fisher Scientific). Both CCA cell lines were tested for mycoplasma using MycoAlertâ„¢ PLUS Mycoplasma Detection Kit (Lonza, Walkersville, MD, USA) and were negative. JQ1 (HY-13030, MedChem Express, Monmouth Junction, NJ, USA), I-BET762 (HY-13032, MedChem Express), olaparib (HY-10162, MedChem Express) and veliparib (ABT-888, Enzo Life Sciences, Farmingdale, NY, USA) were prepared as solutions in DMSO. Final concentrations of DMSO in in vitro experiments were <0.3%.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!