The largest database of trusted experimental protocols

Human alt elisa kit

Manufactured by Abcam
Sourced in United Kingdom

The Human ALT ELISA Kit is a quantitative in vitro diagnostic test designed to measure the levels of Alanine Aminotransferase (ALT) in human serum or plasma samples. ALT is an enzyme found primarily in the liver and its measurement can provide information about liver health.

Automatically generated - may contain errors

2 protocols using human alt elisa kit

1

Quantifying Murine Serum ALKP and ALT

Check if the same lab product or an alternative is used in the 5 most similar protocols
AlkP and ALT levels in murine sera were analysed using the Human ALKP ELISA Kit (Thermo Fisher Scientific, #EH19RB) and Human ALT ELISA Kit (#ab234578, Abcam, UK), respectively, following the manufacturer’s specifications.
Results were expressed as U/L.
+ Open protocol
+ Expand
2

Quantification of Liver Injury Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
LDH levels in vascular and hepatic medium supernatants were measured by using the Cytotoxicity Detection KitPLUS (LDH) (Roche, Basel, Switzerland). Therefore, samples were collected from drug-treated liver models every 24 h for up to 72 h. Supernatants were directly diluted 1:2 in LDH storage buffer containing 200 mM Tris (Carl Roth)-HCL (VWR International, Darmstadt, Germany) at pH 7.5, 10% glycerol (Sigma-Aldrich), 1% bovine serum albumin (Sigma-Aldrich) and AQUA AD iniectabilia to conserve LDH activity during freezing. Samples were stored at − 20 °C until performing the assay. Samples were thawed and the assay was performed according to the manufacturer’s instruction. LDH activity was analyzed spectrophotometrically at 490 nm and concentrations were calculated from a standard curve obtained from dilutions of the LDH standard (Tecan Reader infinite F201, Tecan).
The release of ALT into hepatic and vascular culture supernatants was analyzed using the Human ALT ELISA Kit (Abcam). The assay was performed according to the manufacturer’s protocol in a 384-well format with sample and reagent volumes accordingly adopted. ALT levels were determined spectrophotometrically at 450 nm and concentrations were calculated from an ALT standard curve (Tecan Reader infinite F201, Tecan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!