The largest database of trusted experimental protocols

Unify software 1

Manufactured by Waters Corporation

UNIFY Software 1.0.0 is a data acquisition and processing software developed by Waters Corporation. The software provides a platform for controlling various analytical instruments and managing the data generated from these instruments.

Automatically generated - may contain errors

2 protocols using unify software 1

1

LC-QToF-MS Identification of Phenolic Compounds in Corchorus olitorius Leaf Extract

Check if the same lab product or an alternative is used in the 5 most similar protocols
Every phenolic compound in the leaf extract of C. olitorius at the optimized microwave-enhanced extraction conditions was identified using LC-QToF-MS (Waters Vion IMS, USA). A C18 column with the dimension of 100 mm × 2.10 mm × 1.80 µm was used. There are two mobile phases used in this analysis; they are water + 0.1% formic acid (A) and 100% acetonitrile (B). The operating conditions were a seal wash period of 5 min, a pre-injector volume of 0 µL, low pressure of 0 psi, high-pressure limit of 18,000 psi, gradient elution was 90% A and 10% B (1.25 min), 45% A and 55% B (4.17 min), 10% A and 90% B (6.25 min), 90% A and 10% B (8.34 min), with the injection volume of 20 µL, the flow rate of 0.50 mL/min, spray voltage of 4 keV, mass range of 100–1000 m/z, sample temperature of 15 °C, column temperature of 40 °C, gas flow of 0.50 mL/min, desolvation gas flow rate of 800 L/h, desolvation temperature of 550 °C, low collision energy of 4 eV, high collision energy ramp between 10 and 45 eV, source temperature of 120 °C. The identifications of phenolic compounds in the leaf extract of C. olitorius were performed by utilising SYNAPT mass spectrometer (Waters) coupled with an electrospray ionization operated in negative ion mode. Waters® UNIFY Software 1.0.0 installed in equipment was used to identify the phenolic compounds.
+ Open protocol
+ Expand
2

C. loureirii Nees Stem Extract Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The C. loureirii Nees stem extracts were analyzed at the ideal conditions using LC-QTOF-MS supplied with PDA detector (Waters, United States) and asymmetry C18 column of 100 × 2.1 mm, 1.8 mm particle size (Waters, United States). The C. loureirii Nees stem extracts were prepared in high-performance liquid chromatography grade pure methanol to produce 20 ppm. For analysis, the mobile phases used as A (water with 0.1% formic acid) and B (100% acetonitrile). The gradients elution were used as earlier (Alara et al., 2018 (link)), using the injection volume of 20 ml and flow rate of 0.5 ml/min. The bioactive constituents in the C. loureirii Nees stem extracts were tentatively designated with Waters UNIFY Software 1.0.0 (Alara et al., 2018 (link)).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!