The largest database of trusted experimental protocols

2 protocols using β glucuronidase arylsulfatase helix pomatia

1

Methoxyacetylfentanyl Quantification and Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
In this study, case circumstances are presented together with blood concentrations of methoxyacetylfentanyl obtained using a liquid chromatography–tandem mass spectrometric (LC–MS-MS) method alongside urinary metabolite data obtained using liquid chromatography–quadrupole time of flight–mass spectrometry (LC–QTOF–MS).
methoxyacetylfentanyl was obtained from Cayman Chemical (Ann Arbor, MI), and 4-ANPP was obtained from Toronto Research Chemicals (North York, Canada). The internal standard fentanyl-d5 was obtained from Cerilliant (Round Rock, TX). For LC–MS-MS quantification, LC–MS grade acetonitrile, formic acid and methanol were obtained from Fisher Scientific (Gothenburg, Sweden) and ammonium formate from Fluka (Sigma‐Aldrich, Stockholm, Sweden). For sample preparation, gradient grade acetonitrile, methanol and formic acid p.a. (98%) from Merck (Darmstadt, Germany), 95% ethanol from Kemetyl (Haninge, Sweden) and β‐glucuronidase/arylsulfatase (Helix pomatia) from Roche (Mannheim, Germany) were used.
+ Open protocol
+ Expand
2

Quantitative Analysis of Meclonazepam

Check if the same lab product or an alternative is used in the 5 most similar protocols
Meclonazepam was obtained from Chiron A/S (Trondheim, Norway). Liquid chromatography-mass spectrometry (LC-MS) grade acetonitrile (ACN), formic acid, and methanol were purchased from Fisher Scientific (Gothenburg, Sweden). Ammonium formate was obtained from Fluka (Sigma-Aldrich, Stockholm, Sweden) and β-glucuronidase/ arylsulfatase (Helix pomatia) from Roche (Mannheim, Germany). Saline (9 mg/mL sodium chloride) was from Braun (Melsungen, Germany) and 99.5% ethanol from Kemetyl (Haninge, Sweden). HLM (UltraPool™, 150-donor-pool) and NADPH regenerating system solution A and B were purchased from Corning (Corning, NY, US), cryopreserved human hepatocytes (LiverPool™, 10-donor-pool), InVitro G r o H T, a n d I n Vi t r o G r o K H B m e d i a f r o m BioreclamationIVT (Baltimore, MD, USA). High-purity water was produced in-house in a MilliQ Gradient 10 production unit from Millipore (Billerica, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!