The largest database of trusted experimental protocols

9 protocols using tetrakis acetonitrile copper 1 hexafluorophosphate

1

Synthesis of Colloidal Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cadmium oxide (CdO, 99.99%), copper(I) chloride
(CuCl, 99.999%), trioctylphosphine oxide (TOPO, 99%), trioctylphosphine
(TOP, 97%), and selenium powder (Se, 99.99%) were purchased from Strem
Chemicals. Cadmium chloride (CdCl2, 99.99%), iodine (I2, 99.99%), iron(III) chloride (FeCl3, 98%), oleylamine
(70%), tetrakis(acetonitrile)copper(I) hexafluorophosphate, and sulfur
powder (S, 99.9%) were purchased from Sigma-Aldrich. Copper(II) chloride
(CuCl2, 99%) was purchased from Alfa Aesar. Octadecylphosphonic
acid (ODPA) and hexylphosphonic acid (HPA) were purchased from Polycarbon
Industries. Cerium(IV) ammonium nitrate (>98.5%), nitric acid (HNO3, 67−69%), anhydrous toluene and methanol were purchased
from Carlo Erba reagents.
+ Open protocol
+ Expand
2

Synthesis of Semiconductor Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cadmium oxide (CdO, 99.5%), trioctylphosphine
oxide (99%), trioctylphosphine (TOP, 97%), selenium powder (Se, 99.99%),
and lead(II) acetate trihydrate (Pb(CH3CO2)2·3H2O, 99.999%) were purchased from Strem
Chemicals. Octadecylphosphonic acid (99%) was purchased from Polycarbon
Industries. Copper(II) acetylacetonate (Cu(acac)2, 97%),
hexadecylamine (98%), tetrakis(acetonitrile)copper(I) hexafluorophosphate
(99.99%), octadecene (technical grade, 90%), 1-dodecanethiol (≥98%),
oleylamine (70%), tetrachloroethylene (≥99%), anhydrous chloroform,
methanol, toluene, and tetrahydrofuran were purchased from Sigma-Aldrich.
All chemicals were used without any further purification.
+ Open protocol
+ Expand
3

Synthesis of Colloidal Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Diethylzinc solution (1.0 M in hexane), zinc acetate (anhydrous, 99.99%), zinc oxide (ZnO, 99.0%), 1-octadecene (ODE, 90%), oleic acid (OA, 90%), selenium (99.99%), 1-octanethiol (≥98.5%), oleylamine (OLA, 70%), cadmium oxide (CdO, ≥99.99%), trioctylphosphine oxide (TOPO, 99%), diphenylphosphine (DPP, 98%), tetrakis(acetonitrile)copper(I) hexafluorophosphate (97%) and zinc chloride (dry, ≥98.5%) were purchased from Sigma. Trioctylphosphine (TOP, 97%) was purchased from Strem. Octadecylphosphonic acid (ODPA, >99%), tetradecylphosphonic acid (TDPA, >99%) and hexylphosphonic acid (HPA, >99%) were purchased from PCI synthesis. All chemicals were used as received without any further purification.
+ Open protocol
+ Expand
4

Comparative Analysis of Wild-Type and CTR1-Deficient Mouse Fibroblasts

Check if the same lab product or an alternative is used in the 5 most similar protocols
The wild type mouse embryo fibroblast cell line (CTR+/+) and a line established from mice in which both alleles of CTR1 were knocked out (CTR1−/−) were gifts from Dr. Dennis Thiele (Duke University). These cells were grown in DMEM Hi-glucose media with 20% FBS. (Invitrogen, Carlsbad, CA). The human epithelial tumor cell line 2008 was grown in RPMI-1640 media supplemented with 10% FBS. All cells were grown at 37°C and 5% CO2. The 2008-based CTR2 knock down, mCherry, and mCherry-hCTR2 cell lines were grown continuously in 10 μg/mL puromycin supplemented media. cDDP was purchased from Teva Parenteral Medicines, Inc. (Irvine, CA). Mouse monoclonal antibody to hCTR2 was obtained from the National Cancer Institute. Tetrathiomolybdate and Tetrakis(acetonitrile)copper(I)hexafluorophosphate was purchased from Sigma-Aldrich, St. Louis, MO.
+ Open protocol
+ Expand
5

Synthesis of Colloidal Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Molybdenum hexacarbonyl, sulfur powder, tetrakis(acetonitrile)copper(i) hexafluorophosphate (97%), and 1-octadecene (ODE, technical grade 90%) were all purchased from Sigma-Aldrich. Oleylamine (OLA, >50%) was purchased from TCI. The solvents such as hexanes (certified ACS grade) were acquired from Fisher Scientific. Ethanol (200 proof) was brought from Decon Laboratories, Inc. All chemicals were used as received without further purification.
+ Open protocol
+ Expand
6

Copper-Catalyzed Click Chemistry for Oligonucleotides

Check if the same lab product or an alternative is used in the 5 most similar protocols
4-ethynylaniline (HC ---CC 6 H 4 NH 2 ), 4-azidoaniline hydrochloride (N 3 C 6 H 4 NH 2 • HCl), sodium nitrite (NaNO 2 ), tris[(1-benzyl-1H-1,2,3-triazol-4-yl)methyl]amine (TBTA), tetrakis(acetonitrile)copper(I) hexafluorophosphate (TCH), (+)-sodium L-ascorbate (SA), dimethyl sulfoxide (DMSO), acetonitrile (ACN), iron(III) chloride hexahydrate (FeCl 3 • 6 H 2 O), potassium chloride (KCl), hydrochloric acid (HCl, 37 %), isopropyl alcohol (IPA) and acetone were purchased from Sigma Aldrich (Belgium). All reagents were used without further purification. Alkyne-and azide-modified oligonucleotides (25mer) were purchased from IDT (Belgium) (sequences in Supporting Information).
+ Open protocol
+ Expand
7

Biofunctionalized Silane Coatings Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methyltrimethoxysilane (98% purity, MTMS), (3-mercaptopropyl)trimethoxysilane (95% purity, MPTMS), hexadecyltrimethylammonium bromide (98% purity, CTAB), methanol (99.8%, MeOH) and tetrakis(acetonitrile)copper(I) hexafluorophosphate were acquired from Sigma Aldrich. Oxalic acid, vinyltrimethoxysilane (97% purity, VTMS), Ellman's reagent (5,5′-dithiobis-(2-nitrobenzoic acid) or DTNB) and sodium azide (NaN 3 ) were from Merck. (3-Chloropropyl)-trimethoxysilane (97% purity; CPTMS) and (3-methacryloxypropyl)trimethoxysilane (98% purity, MAPTMS) were purchased from ABCR. Propiolic acid (98%) was obtained from Acros Organics. Ammonium hydroxide (28% in H 2 O), sodium carbonate (Na 2 CO 3 ), potassium permanganate (KMnO 4 ), N,N-dimethylformamide (DMF), acetonitrile (ACN) and sodium azide were procured from VWR.
+ Open protocol
+ Expand
8

Synthesis of Colloidal Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Copper(I) chloride (CuCl, 99.99% extra pure), ethanol (EtOH, 99.5%, extra dry) and silver nitrate (99.85%) were purchased from Acros Organics. Selenium (Se, 99.999%, 200 mesh), methanol (MeOH, 99.9%, anhydrous), toluene (99.8%, anhydrous packed under argon) and n-butanol (99.9% packed under argon) were purchased from Alfa Aesar. Sulfur (S, 99.98%), tetrakis (acetonitrile)copper(I) hexafluorophosphate ([Cu(CH 3 CN) 4 ]PF 6 , 97%), dodecylamine (DDA, 98%), didodecyl-dimethylammonium bromide (DDAB, 98%), octadecene (ODE, 90%) and oleylamine (OLA, >70%) were purchased from Sigma Aldrich. Gold(III) chloride (99%) was purchased from ABCR. Hydrochloric acid (>37%, for trace analysis) and nitric acid (>69%, for trace analysis) were purchased from Fluka.
Pre-degassed OLA and ODE were prepared by placing each solvent in a separate flask and heating them under reflux (≤1 × 10 -3 mbar, 115 °C) for 6 h, while purging them multiple times with argon. Afterwards they are transferred and stored inside the glove box under inert gas.
All other chemicals were used without further purification.
If not otherwise mentioned all experiments have been done under argon using standard Schlenk line techniques or were done inside a nitrogen filled glove box.
+ Open protocol
+ Expand
9

Synthesis of Colloidal Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals 1-Octadecene (ODE, 90%), oleic acid (90%) and 1-octylamine (99%) were purchased from Alfa Aesar. 1-Octanethiol (OT, 98.5%), 1-octadecanethiol (ODT, 98%), 1-dodecanethiol (DDT, 98%), 1-hexadecanethiol (HDT, 95%), trioctylphosphine (TOP, 97%), tetrakis(acetonitrile)copper(I) hexafluorophosphate (97%), cadmium nitrate tetrahydrate (Cd(NO 3 )•4H 2 O, 99%) and cadmium acetate dihydrate (98%) were obtained from Sigma-Aldrich. Selenium powder (99.99%) was purchased from Strem. Na(myristate) (98%) was purchased from TCI.
All chemicals were used directly without purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!