The largest database of trusted experimental protocols

Granzyme b percp

Manufactured by Novus Biologicals

Granzyme B-PerCP is a flow cytometry reagent used for the detection and quantification of granzyme B-positive cells. Granzyme B is a serine protease enzyme involved in the process of apoptosis. The PerCP (Peridinin Chlorophyll Protein Complex) fluorophore is conjugated to the anti-granzyme B antibody, enabling its detection and measurement by flow cytometry.

Automatically generated - may contain errors

5 protocols using granzyme b percp

1

Comprehensive Immune Profiling of PBMC Populations

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following panel of antibodies was used for analysis of PBMC populations: CD8-PE-Cy7 (BD Pharmingen, clone RPA-T8, catalog 304006), CD11a-APC (BioLegend, clone HI111, catalog 301212), PD-1 FITC (BioLegend, clone EH12.2H7, catalog 32990), CX3CR1-APC/Cy7 (BioLegend, clone 2A9-1, catalog 341616), Bim-PE (Cell Signaling Technology, Danvers, Massachusett, clone C34C5, catalog 12186S), Ki-67-BV421(BD Biosciences, clone B56, catalog 562899), Granzyme B-PerCP (Novus Biologicals, Danvers, Massachusett, clone CLB-GB11, catalog NBP1-50071PCP). CD8+ T-cells were first stained for surface markers followed by intracellular staining. Flow cytometry data were collected on a CytoFLEX LX (Beckman Coulter, Atlanta, Georgia). Flow cytometry analysis was performed with FlowJo software 10.4 (Tree Star, Palo Alto, California).
+ Open protocol
+ Expand
2

Immunophenotyping of PBMC Populations

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following panel of antibodies was used for analysis of PBMC populations: CD8-PE-Cy7 (BD Pharmingen, clone RPA-T8, catalog 304006), CD11a-APC (BioLegend, clone HI111, catalog 301212), PD-1 FITC (BioLegend, clone EH12.2H7, catalog 32990), CX3CR1-APC/Cy7 (BioLegend, clone 2A9–1, catalog 341616), Bim-PE (Cell Signaling Technology, clone C34C5, catalog 12186S), Ki-67-BV421(BD Biosciences, clone B56, catalog 562899), Granzyme B-PerCP (Novus Biologicals, clone CLB-GB11, catalog NBP1–50071PCP). CD8+ T-cells were first stained for surface markers followed by intracellular staining. Flow cytometry data was collected on a CytoFLEX LX (Beckman Coulter). Flow cytometry analysis was performed with FlowJo software 10.4 (Tree Star).
+ Open protocol
+ Expand
3

Multiparametric Immune Cell Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral Blood Mononuclear Cells values were isolated, and subpopulations were identified with the following antibody panel: CD8-PE-Cy7 (BD Pharmingen, clone RPA-T8, catalog 304006), CD11a-APC (BioLegend, clone HI111, catalog 301212), PD-1 FITC (BioLegend, clone EH12.2H7, catalog 32990), Bim-PE (Cell Signaling Technology, clone CD34C5, catalog 12186S), Granzyme B-PerCP (Novus Biologicals, clone CLB0GB11, catalog NBP1–50071PCP), and CX3CR1-APC/Cy7 (BioLegend, clone 2A9–1, catalog 341616). Flow cytometry was performed on a CytoFLEX LX (Beckman Coulter, Atlanta, Georgia). Data were analyzed with FlowJo, version 10.6.1.
+ Open protocol
+ Expand
4

Multiparametric Immune Cell Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral Blood Mononuclear Cells values were isolated, and subpopulations were identified with the following antibody panel: CD8-PE-Cy7 (BD Pharmingen, clone RPA-T8, catalog 304006), CD11a-APC (BioLegend, clone HI111, catalog 301212), PD-1 FITC (BioLegend, clone EH12.2H7, catalog 32990), Bim-PE (Cell Signaling Technology, clone CD34C5, catalog 12186S), Granzyme B-PerCP (Novus Biologicals, clone CLB0GB11, catalog NBP1–50071PCP), and CX3CR1-APC/Cy7 (BioLegend, clone 2A9–1, catalog 341616). Flow cytometry was performed on a CytoFLEX LX (Beckman Coulter, Atlanta, Georgia). Data were analyzed with FlowJo, version 10.6.1.
+ Open protocol
+ Expand
5

Phenotyping of Cytotoxic T Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
PBMC were stained for flow cytometry assays in FACS buffer (1X PBS, 2 mM EDTA and 3% FBS) with the following antibody panel: CD8-PE-Cy7 (BD Pharmingen, clone RPA-T8, catalog 304006), CD11a-APC (BioLegend, clone HI111, catalog 301212), CX3CR1-APC/Cy7 (BioLegend, clone 2A9-1, catalog 341616), Granzyme B-PerCP (Novus Biologicals, clone CLB-GB11, catalog NBP1-50071PCP). Live/Dead fixable stain kit was used to distinguish live cells (Thermo Fisher Scientific, L34961). Data acquisition was performed on a CytoFLEX LX (Beckman Coulter). We analyzed flow cytometry data with FlowJo 10.4 (Tree Star).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!